Electric Starting Motor
Show/hide table
Illustration 1 | g02849397 |
Show/hide table
Specification for 117-8846 Electric Starting Motor Gp | |||
Item | Qty | Part | Specification Description |
1 | 4 | 6V-8188 Nut | Torque to |
2 | 1 | 242-7979 Solenoid As | Current consumption (draw) at 30 V and at 1. For Pull-in windings is 38 amp 2. For Hold-in windings is 6 amp |
B | - | - | The clearance between the pinion and the housing is |
3 | 2 | 4B-2049 Nut | Torque to |
4 | 2 | 6V-8188 Nut | A maximum of three cable terminals or wire terminals may be used with the battery terminal nut (3). A maximum of two of the terminals may be equal to or greater than 0 AWG.
Torque to |
- | - | - | When the electric starting motor is viewed from the pinion end, the motor rotates in the clockwise direction.
No load conditions at 1. Speed is 6500 ± 1000 rpm 2. Current draw is 87.5 ± 12.5 Amp 3. Voltage is 30 VDC |
Caterpillar Information System:
3406E and 3456 Industrial Engines Air Starting Motor Pressure Regulating Valve
3408C and 3412C Marine Engines Air Starting Motor
3034 Engine for Caterpillar Built Machines Cooling System
3176C and 3196 Industrial Engines Cylinder Block
3034 Engine for Caterpillar Built Machines Lubrication System
3406E and 3456 Industrial Engines Electric Starting Motor
3176C and 3196 Industrial Engines Coolant Conditioner Base
C-10 and C-12 Industrial Engines Belt Tightener
C-10 and C-12 Truck Engines Belt Tensioner
3116 Truck Engines Belt Tensioner
3406E and 3456 Industrial Engines Alternator
3176C and 3196 Industrial Engines Water Temperature Regulator
3034 Engine for Caterpillar Built Machines Electrical System
3176C and 3196 Engines for Caterpillar Built Machines Cylinder Liner Projection
3176C and 3196 Engines for Caterpillar Built Machines Main Bearing Journal
3408E and 3412E Industrial Engines Engine Speed/Timing Sensors - Check/Clean/Calibrate
3176C Engine Connecting Rod Bearing Journal
3176C and 3196 Industrial Engines Connecting Rod Bearing Journal
3176C and 3196 Industrial Engines Connecting Rod
Electronic Modular Control Panel II+ (EMCP II+) Component Location - For 3412C, 3508, 3512, and 3516 MUI Engines (Including Paralleling) and 3412C Engines With Paralleling
C175-16 Locomotive Engines After Starting Engine
3176C Engine Piston and Rings
C175-16 Locomotive Engine Fuel Conservation Practices
3500B Locomotive Engines Emergency Stopping