Alternator and Regulator
Show/hide table
Illustration 1 | g01431633 |
Voltage ... 12 V
Amperage ... 51 Amp
Note: Load the battery with a carbon pile 4C-4911 Battery Load Tester in order to get the maximum alternator output.
Polarity ... Negative ground
Rotation ... Either direction
Minimum full load current at 5000 rpm ... 45 Amp
Minimum full load current at 1500 rpm ... 14.5 Amp
Output voltage ... 13.8 ± 0.2 V
(1) Shaft nut
- Torque ...
60 ± 7 N·m (44 ± 5 lb ft)
(2) Terminal nuts
- Torque ...
2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Terminal nut
- Torque ...
4.1 ± 0.4 N·m (36 ± 4 lb in)
(4) Regulator
- Voltage setting ... No adjustment
- Permissible voltage range ... 13.6 to 14 V
Caterpillar Information System:
G3304 and G3306 Engines Alternator and Regulator
3176C and 3196 Marine Engines Alternator and Regulator
3176C and 3196 Marine Engines Flywheel
3524B Engines for 797 and 797B Off-Highway Trucks Ether Control System
3176C and 3196 Marine Engines Engine Oil Pressure
3176C and 3196 Marine Engines Water Temperature Regulator
793B Off-Highway Truck Front Wheel Oil - Inspect
3176C and 3196 Engines for Caterpillar Built Machines Crankshaft
3500B and 3500B High Displacement Generator Set Engines Engine Design
3500B and 3500B High Displacement Generator Set Engines Engine Design
3176C and 3196 Marine Engines Camshaft
3176C and 3196 Marine Engines Atmospheric Pressure Sensor
3306B Industrial Engine Fuel Pressure Indicator
Electric Protection System Energize-To-Shutoff (ETS) For Generator Set, Industrial and Marine Diesel Engines ETS Junction Box-Switchgear Not Required (OP,WT,OS)
3612 and 3616 Fast Vessel Engines Zinc Rods - Inspect/Replace
3176C and 3196 Marine Engines Cylinder Head Valves
Spring Isolator Group Installation and Adjustment Procedure {7060} Spring Isolator Group Installation and Adjustment Procedure {7060}
3412 Generator Set Engines Electric Starting Motor
Electric Protection System Energize-To-Shutoff (ETS) For Generator Set, Industrial and Marine Diesel Engines ETS Junction Box-Switchgear Required (OP,WT,OS)
Electric Protection System Energize-To-Shutoff (ETS) For Generator Set, Industrial and Marine Diesel Engines ETS Junction Box-Switchgear Not Required (OP,WT)
3500B Engines Housing (Front)
3176C and 3196 Marine Engines Electric Starting Motor
3176C Engine Electric Starting Motor
3176C and 3196 Marine Engines Electric Starting Motor