Use 153-9630 PWM-Analog Test Group-Sensor Adapter Kit For DataView {1000,3000,4000,5000,6000,0788}
Usage:
Electronically Controlled Cat®
Equipment
Warranty Category: Y
Features/Benefits
-
- * Used to test CAT® PWM and analog sensors on or off the machine
- * Used with 131-5050 DataView and DataView 2.0 software
- * DataView 2.0 software lists common sensors for easy setup
- * Internal power supply powers active sensors while removed from equipment
- * CE certified for European use
- * Recommended tool
- * Used to test CAT® PWM and analog sensors on or off the machine
Specifications/Technical Information
- Input impedance - 120 k/Omega/
- Input voltage - 5 VDC (from DataView)
- Output voltage - 9.4 VDC (sensor power)
- Maximum sensor current - 40 mA maximum at 9.4 VDC
- Operating temperature - -17 to 60°C (0 to 140°F)
- Size - 85 x 56 x 35 mm (3.3 x 2.2 x 1.4 in)
- Weight (153-9625) - 0.23 kg (.5 lb)
- Input voltage - 5 VDC (from DataView)
153-9630 Test Group, Sensor
Reference
Tool Operating Manual; NEHS0711, Caterpillar PWM/Analog Adapter Sensor Kit for DataView
Caterpillar Information System:
1998/12/07 Use 143-4062, 143-4065, 143-4066 Auto ID Pressure Sensors With DataView {1000,3000,4000,5000,6000,0788}
1998/12/07 Improved Battery Cable Available {1402}
1998/12/07 Use 153-8537 A/C Component To Flush Air Conditioning Systems And Recycle Solvent {0757}
1998/12/07 Use 150-1782 Crossblock For 8B-7548 Push Puller
1998/12/07 Use 149-5138 Mechanical Push/Puller For Extra Force In General Purpose Applications {0700}
1998/12/07 New 146-4080 Digital Multimeter Available For Troubleshooting Electronic Circuits {0115}
1998/12/07 Use 145-9342 Filter Crusher To Reduce Waste And Collect Oil {5720,0800}
1998/12/07 Use 144-0235 Belt Tension Gauge to Check Belt Tension {1357}
1998/12/07 Use 9U-5968 Hydrostatic Filter Group To Filter Contaminanted Oil {5050,5095,3030,3080}
1998/12/07 Use 131-5050 DataView Group And 131-5051 DataView Portable TechStation Group For Accurate Diagnostics {1000,3000,4000,5000,6000,0788}
1998/12/07 Identification Of External Terminals On Alternators {1405,1406,1400}
1998/11/30 Proper Flushing And Charging Of Air Conditioner Refrigerant System {7320}
1998/12/28 Use 1Y-3904 Clear Adhesive Sealant For O-Ring Assembly{0649}
1998/12/28 Use 160-0772, 160-0774/ And 160-0775 Wire Brushes For Tough Cleaning Jobs{0674}
1999/01/18 Service Literature Index For Starting Motors And Alternators {1405,1453}
1999/02/01 Procedure For Assembly And Installation Of Conventional Duo-Cone Seals Is Now Available{7561}
1999/02/08 Correct Seal Usage Improves Service Life {7555}
1999/02/22 Shielded Metal Arc Welding And Flux Cored Arc Welding Information {0679}
1999/03/08 Use 157-3719 Spanner For Removing And Installing Bosch Fuel Pumps {1251}
1999/03/08 Use 170-9227 Reamer Shims To Aid In Reaming Engine Injector Sleeves {1254}
1999/03/08 Use 154-9521 Spark Plug Seat Cleaner To Remove Debris From Gasket Seat And Cylinder Heads {1100,0703}
1999/03/08 Use 138-8447 Aerosol Rust Preventative As A Corrosion Inhibitor {0645}
1999/03/08 New 150-7762 And 150-7745 (Trailer Mounted) Hot Water Pressure Washers For Cleaning Large Components {0680}
1999/03/08 New 152-8256 (115V) And 154-4853 (220V) Air Conditioning Refrigerant Recovery, Recycling, And Manual Recharging Station For R134A Refrigerant {7320,1809}