Usage:
(1) Tighten the nuts to a torque of ... 27 ± 7 N·m (20 ± 5 lb.ft.)
(2) Tighten the clamps to a torque of ... 4.5 ± 0.5 N·m (40 ± 5 lb.in.)
On new hoses, tighten the clamps to a torque of ... 7.5 ± 0.5 N·m (65 ± 5 lb.in.)
(3) Tighten bolt assemblies to a torque of ... 4.0 ± 0.5 N·m (35 ± 4 lb.in.)
(4) Tighten the bolts that hold the air cleaner group in position to a torque of ... 100 ± 15 N·m (75 ± 10 lb.ft.)
(5) Tighten the bolts in the adapter assembly to a torque of ... 45 ± 7 N·m (32 ± 5 lb.ft.)
Panel Type - Single Stage Air Cleaners
(1) Cylinder head bolt used with air cleaner groups that have a long brace.
Put 5P3931 Anti-Seize Compound on the threads of the bolt before it is installed.
Tighten the bolt to a torque of ... 43 ± 7 N·m (32 ± 5 lb.ft.)
(2) Tighten the bolts that hold the air cleaner housing to the support assembly to a torque of ... 25 ± 7 N·m (18 ± 5 lb.ft.)