Usage:
(1) Tighten studs in the governor drive housing to a torque of ... 15 ± 5 N·m (11 ± 4 lb.ft.)
Tighten nut on studs to a torque of ... 15 ± 5 N·m (11 ± 4 lb.ft.)
Linkage Adjustment
(2) Lever. With actuator output shaft in shutoff position, install lever so angle (D) between the lever and vertical is ... 18°
Rotation of lever (2) from shutoff to full load position [angle (B)] is ... 42°
(3) Lever. With control shaft of governor drive in the shutoff position, install lever so angle (C) between the lever and vertical is ... 28°
Rotation of lever (3) from shutoff to maximum fuel position [angle (A)] is ... 16°
(4) Rod assembly. With levers (2) and (3) in the shutoff position, adjust rod assembly to fit between the levers.
(Woodward PSG)
(1) Tighten studs in the governor drive housing to a torque of ... 15 ± 5 N·m (11 ± 4 lb.ft.)
Tighten nut on studs to a torque of ... 15 ± 5 N·m (11 ± 4 lb.ft.)
Linkage Adjustment
(2) Lever. With control shaft of governor drive in the shutoff position, install lever so angle (C) between the lever and vertical is ... 28°
Rotation of lever (2) from shutoff to maximum fuel position [angle (A)] is ... 16°
(3) Rod assembly. With levers (2) and (4) in the shutoff position, adjust rod assembly to fit between the levers.
(4) Lever. With governor control shaft in the shutoff position, install lever so angle (B) between the lever and vertical is ... 30°
Rotation of lever (4) from shutoff to full load position [angle (B)] is ... 30°