AP600D, AP655D, BG600D and BG655D Asphalt Pavers Caterpillar


MID 157 - CID 2554 - FMI 06

Usage:

BG655D B5D
Conditions Which Generate This Code:


Illustration 1g01370822

Schematic of the Right Hopper Lower Solenoid

This diagnostic code is associated with the Right Hopper Lower Solenoid. The FMI 06 means that the RH Operator ECM has detected that the current for the solenoid circuit is above normal.

Note: The RH Operator ECM is located under the RH Operator platform.

Conditions that could causes this diagnostic code to be activated are:

  • The energize circuit of the solenoid is shorted to a ground source.

  • The solenoid has failed.

  • The ECM has failed. This is unlikely.

System Response:

When this diagnostic code is active, the following occurs:

  • Right hopper lower is disabled.

  • Operator station fault lamp is active.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

Note: The resistance of the solenoid coil should be 27 ± 1.4 ohms at 20 °C (68.0 °F).

Test Step 1. CHECK THE SOLENOID

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. Observe the status of the diagnostic code.

  1. Disconnect the machine harness at the solenoid for the Hopper Lower hydraulic valve.

Expected Result:

The active CID 2554 FMI 06 diagnostic code changes to a CID 2554 FMI 05 diagnostic code when the solenoid is disconnected.

Results:

  • YES - The active CID 2554 FMI 06 diagnostic code changes to a CID 2554 FMI 05 diagnostic code when the solenoid is disconnected. The solenoid circuit in the machine harness is correct.

    Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. The resistance of the solenoid coil should be 27 ± 1.4 ohms at 20 °C (68.0 °F). Replace the solenoid.

    STOP

  • NO - The CID 2554 FMI 06 diagnostic code remains active. Disconnecting the solenoid did not change the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.

Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND

The solenoid remains disconnected from the machine harness.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness ECM connectors J1 and J2 from the ECM.

  1. At the machine harness ECM connectors, measure the resistance from the signal contact J2-2 (wire A859-PU) to frame ground. Measure the resistance from the signal contact J2-2 (wire A859-PU) to all of the other contacts that are used in J1 and J2 ECM connectors.

  1. While observing the multimeter resistance measurements, wiggle the machine harness connectors for the ECM and the solenoid. Gently pull on the wires and move the wires around.

Expected Result:

Each resistance measurement is greater than 5000 ohms at all times during the manipulation of the harness and connectors.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - One or more of the resistance measurements is less than 5000 ohms. The resistance measurement is indicating that a short is present in the machine harness. The short is between wire A859-PU and either frame ground or the circuit with the low resistance measurement.

    Repair: For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, corrosion, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the sensor circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the CID 2554 FMI 06 diagnostic code.

Expected Result:

The CID 2554 FMI 06 diagnostic code is still active.

Results:

  • YES - The CID 2554 FMI 06 diagnostic code is still active. The diagnostic code has not been corrected.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again. If the cause of the problem is not found, the ECM may have failed.Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 2554 FMI 06 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

IT38H Integrated Toolcarrier and 938H Wheel Loader Machine Systems Main Control Valve - Install
CB22, CB24, CB32 and CC24 Utility Compactors Fuel Injector - Test/Change
14L Motor Grader Machine Systems Bank Valve - Assemble - Front Frame
14L Motor Grader Machine Systems Bank Valve - Disassemble - Front Frame
14M Motor Grader Machine Systems Bank Valve - Install - Front Frame
14M Motor Grader Machine Systems Bank Valve - Remove - Front Frame
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2554 - FMI 05
AP655D Asphalt Paver Machine Systems Pump Drive - Install
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2554 - FMI 03
AP655D Asphalt Paver Machine Systems Pump Drive - Remove
938H Wheel Loader and IT38H Integrated Toolcarrier Machine Systems Radiator Cap
2007/03/26 Direct Shipping Process and New Packaging for Replacement Glass {7301, 7308, 7310, 7325}
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2571 - FMI 03
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2571 - FMI 05
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2571 - FMI 06
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2572 - FMI 03
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2572 - FMI 05
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2572 - FMI 06
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2584 - FMI 03
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2584 - FMI 05
AP600D, AP655D, BG600D and BG655D Asphalt Pavers MID 157 - CID 2584 - FMI 06
AS3251C Asphalt Screed Fuel Pump Control
AP655D and BG655D Asphalt Pavers Propel System Location of Hydraulic Components (Propel System)
AS3251C Asphalt Screed Thickness Control
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.