The pump on time has increased for the Automatic Lubrication System (Hydraulic Type). Increasing the pump on time allows the lubrication pump more time to complete a cycle.
The pump on time has increased from two minutes to five minutes.
This change is adaptable for all the above listed machines installed with an automatic lubrication system (hydraulic type). To adjust the pump on time to five minutes refer to "Adjust (Set) the 1DE3546 Electronic Control (Timer) " or "Adjust (Set) the 1DE2617 Electronic Control (Timer) ".
Adjust (Set) the 1DE3546 Electronic Control (Timer)
Illustration 1 | g01149820 |
(1) 1DE3546 Electronic control (timer) |
Illustration 2 | g01150553 |
Electronic control (timer) with the lid removed (A) DSW1 delay time switches (B) DSW2 pump on time switches (C) DSW3 option switches |
Note: DSW1 and DSW2 switches must be set with the engine start switch and the battery disconnect switch in the OFF position. Changes to the switch settings while the electronic control is activated will not be recognized.
DSW2 switches (B) are used to set the pump on time sequence.
Illustration 3 | g01313722 |
View of the DSW2 pump on time switches |
Note: The shaded area is the switch position.
Change the setting for the DSW2 pump on time switch. Refer to Illustration 3.
Adjust (Set) the 1DE2617 Electronic Control (Timer)
Illustration 4 | g01147209 |
(1) 1DE2617 Electronic control (timer) |
Illustration 5 | g01313720 |
Electronic control (timer) with the lid removed (A) DSW1 delay time switches (B) DSW2 pump on time switches (C) DSW3 option switches |
Note: DSW1 and DSW2 switches must be set with the engine start switch and the battery disconnect switch in the OFF position. Changes to the switch settings while the electronic control is activated will not be recognized.
DSW2 switches (B) are used to set the pump on time sequence.
Illustration 6 | g01314361 |
Note: The shaded area is the switch position.
Change the setting for the DSW2 pump on time switch. Refer to Illustration 6.