TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Caterpillar


VREF-A Error IQAN XT2 A0

Usage:

TK711 101
Conditions Which Generate This Code:

This diagnostic code is associated with the 5 VDC power supply for the IQAN XT2 A0 module. The "VREF-A Error" code means that some factor is overwhelming the ability of the module to regulate the source voltage between 4.9 VDC and 5.1 VDC.

The possible causes of the diagnostic code are listed:

  • A short or open may have occurred on the circuits for any of the voltage inputs to the module.

Note: Refer to the complete machine schematic for the connections of these inputs with the IQAN XT2 A0 module.

Test Step 1. CHECK FOR AN OPEN CIRCUIT.

  1. Turn the disconnect switch and the key start switch to the OFF position.

  1. Disconnect the machine harness connectors from the IQAN XT2 A0 module.

  1. At the machine harness connector for the module, check the continuity to ground of the switch contacts with the switch that is activated and with the switch that is not activated. Refer to the complete machine schematic.

Expected Result:

The continuity check is NOT correct.

Results:

  • YES - The continuity check is NOT correct. The harness or the switch is faulty. Proceed to Test Step 2.

  • NO - The continuity check is correct. Proceed to Test Step 3.

Test Step 2. CHECK THE SWITCH.

  1. Disconnect the machine harness from the switch.

  1. Check the continuity to ground of the switch contacts with the switch that is activated and with the switch that is not activated.

Expected Result:

The continuity check is NOT correct.

Results:

  • YES - The continuity check is NOT correct. The switch is malfunctioning.

    Repair: Repair the switch or replace the switch.

    STOP

  • NO - The continuity check is correct.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK FOR A SHORT TO +BATTERY

  1. At the machine harness connector for the module, check the continuity from each of the wires for the switch contact to the contact IQAN XT2 A0-12 (wire A982-OR).

Expected Result:

Continuity exists between the source of the battery voltage and the switch circuit.

Results:

  • YES - Continuity exists between the source of battery voltage. The machine harness is faulty.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

  • NO - Continuity does not exist between the source of battery voltage and the switch circuit. The machine harness is correct. It is unlikely that the module is faulty. Exit this procedure and perform this procedure again.

    Repair: If the cause of the diagnostic code is not found, replace the module.

    STOP

Caterpillar Information System:

TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes VREF-B Error IQAN XP2 A1
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes VREF-A Error IQAN XP2 A1
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes VREF-C Error IQAN XP2 A0
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes VREF-B Error IQAN XP2 A0
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes VREF-A Error IQAN XP2 A0
RM-500 Soil Stabilizer Application Guidelines - For the Spray Systems
2013/08/21 Improved Software for Caterpillar Digital Voltage Regulator (CDVR) Now Available {4467, 7620}
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes High Supply Voltage IQAN XT2 A0
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes High Supply Voltage IQAN XP2 A1
Cease Operation of Certain 914G, 924G, 928G, 930G and IT14G Wheel Loaders and Integrated Toolcarriers{4269} Cease Operation of Certain 914G, 924G, 928G, 930G and IT14G Wheel Loaders and Integrated Toolcarriers{4269}
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes High Supply Voltage IQAN XP2 A0
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes High Supply Voltage IQAN MDM
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Module is Off-Line IQAN Lx A1
793D Off-Highway Truck/Tractor Accumulator (Steering) - Remove
793D Off-Highway Truck/Tractor Accumulator (Steering) - Install
Installation of the AccuGrade® Electronic Components{7220} Installation of the AccuGrade® Electronic Components{7220}
C15 and C18 Petrolem Generator Set Engines Coolant Contains Oil
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Module is Off-Line IQAN XP2 A0
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 1482 - FMI 03
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Power Train Electronic Control System MID 027 - CID 1482 - FMI 04
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Module is Off-Line IQAN XP2 A1
3524B and C175 Engines for Off-Highway Truck/Tractors Engine Design
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Module is Off-Line IQAN XT2 A0
814F Series 2 Wheel Dozer, 815F Series 2 Soil Compactor and 816F Series 2 Landfill Compactor Braking System Brake Control Valve (Service)
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.