Expansion Tank And Heat Exchanger As A Unit
Usage:
Remove Expansion Tank And Heat Exchanger As A Unit
1. Drain the coolant from the cooling system and the water from the expansion tank.
2. Loosen the clamp on four hoses (1). Slide the hoses off the pipes.
3. Disconnect hoses (2) and (3).
4. Remove two bolts (4).
5. The weight of the expansion tank and heat exchanger is 68 kg (150 lb.). Fasten a hoist to the expansion tank.
6. Remove bolts (6) and expansion tank (5) from the engine.
Install Expansion Tank And Heat Exchanger As A Unit
1. Put expansion tank and heat exchanger (2) in postion on bracket (1), and install the bolts that hold it.
2. Install two bolts (5).
3. Connect hoses (3) and (4).
4. Slide four hoses (6) into position, and tighten the clamps that hold them.
5. Fill the cooling system with coolant to the correct level. See the Maintenance Guide.
Caterpillar Information System:
3304B & 3306B MARINE ENGINES Heat Exchanger
3304B & 3306B MARINE ENGINES Sea Water Pump
3304B & 3306B MARINE ENGINES Water Pump
3304B & 3306B MARINE ENGINES Water Temperature Regulator
3304B & 3306B MARINE ENGINES Air Cleaner Group
3304B & 3306B MARINE ENGINES Tachometer Drive
3304B & 3306B MARINE ENGINES Service Meter
3304B & 3306B MARINE ENGINES Flywheel Housing
3304B & 3306B MARINE ENGINES Crankshaft Rear Seal And Wear Sleeve
3304B & 3306B MARINE ENGINES Flywheel
3304B & 3306B MARINE ENGINES Piston Cooling Orifices
3304B & 3306B MARINE ENGINES Crankshaft
3304B & 3306B MARINE ENGINES Oil Pan
3304B & 3306B MARINE ENGINES Oil Pan Plate
3304B & 3306B MARINE ENGINES Oil Pump (3304)
3304B & 3306B MARINE ENGINES Oil Pump (3306)
3304B & 3306B MARINE ENGINES Oil Pump
3304B & 3306B MARINE ENGINES Front Power Take-Off
2301 ELECTRIC GOVERNOR FOR GENERATOR SET AND INDUSTRIAL ENGI Systems Operation
2301 ELECTRIC GOVERNOR FOR GENERATOR SET AND INDUSTRIAL ENGI Testing and Adjusting
2301 ELECTRIC GOVERNOR FOR GENERATOR SET AND INDUSTRIAL ENGI Introduction
2301 ELECTRIC GOVERNOR FOR GENERATOR SET AND INDUSTRIAL ENGI Problem Index
2301 ELECTRIC GOVERNOR FOR GENERATOR SET AND INDUSTRIAL ENGI Problem No. 1: Fuel Linkage Has Limited Travel, Binds, Or Takes Excessive Force
2301 ELECTRIC GOVERNOR FOR GENERATOR SET AND INDUSTRIAL ENGI Problem No. 2: Engine Will Not Start