Usage:

12H AMZ
The "Units" menu has five dialogs which allow you to select the units to show distance, speed, grade, cross slope, and station. In each dialog the current setting is highlighted.

Perform the following steps in order to set the units.

  1. Start the Display in Service Mode.

  1. From the "Setup Menu – Configuration" dialog, press the "Installation" soft key in order to list the items under the "Setup Menu - Installation" dialog.

  1. Use down arrow key or the up arrow key until "Units" is highlighted.



    Illustration 1g01023989

  1. Press the "OK" key. By default, the "Distance Units" dialog is selected. The dialog in Illustration 1 appears.

  1. Do the following as necessary from any of the "Units" dialogs.

    • Press the "Distance" soft key in order to select the distance units.

    • Press the "Speed" soft key in order to select the speed units.

    • Press the "Grade" soft key in order to select the grade units.

    • Press the "Cross Slope" soft key in order to select the cross slope units.

    • Press the "Station Format" soft key in order to select the station (chainage) format for a road design.

    • Press the "ESC" key in order to cancel and return to the "Setup Menu – Installation" dialog.

  1. When any or all of the units have been set, press the "OK" key in order to save the settings and return to the "Setup Menu – Installation" dialog. You can begin to enter details such as the machine dimensions, in those units immediately.

  1. Press the "ESC" key in order to exit the "Setup Menu – Installation" dialog.

    The Units are saved in the Display Settings file.

Distance

Distance values appear on the screen in the following formats.

  • Meters - as "m" (default for all Display firmware files except for US English)

  • International feet - as "ft"

  • US survey feet – as "FT" (default for US English Display firmware)

Perform the following steps in order to change the distance units.

  1. If any other unit setup dialog is shown, press the "Distance" soft key.

  1. Use the down arrow key and the up arrow key in order to choose the required distance units.

Note: The DXF file format does not contain any information on the units used (feet or meters). As all DXF drawing files are unitless, use the SiteVision Office software in order to ensure that the correct units are set.

Note: If you change your units, any currently displayed Site Map and Background Plan files are reloaded. Then the Site Map and Background Plan files are displayed in the new units.

Speed

Speed can be shown in the following formats.

  • Kilometers per hour - as "km/h" (default for all Display firmware files except for US English)

  • Miles per hour - "mph"

Perform the following steps in order to change the speed units.

  1. Press the "Speed" soft key .

  1. Use the down arrow key and the up arrow key in order to choose the required units.

Grade

Grade values can be shown in the following formats:

  • Percentage - as "%"

  • Ratio - as "rise: run" (default)

Perform the following steps in order to change the grade units.

  1. Press the "Grade" soft key .

  1. Use the down arrow key and the up arrow key in order to choose the required format.

Cross Slope

Cross slope values can be shown in the following formats:

  • Percentage - as "%" (default)

  • Ratio - as "rise: run"

Perform the following steps in order to change the cross slope units.

  1. Press the "Cross Slope" soft key .

  1. Use the down arrow key and the up arrow key in order to choose the required format.

    A positive value indicates a rising cross slope as you move away from the master alignment. A negative value indicates a falling cross slope as you move away from the master alignment.

Station Format

Station (chainage) values can be shown in the following formats:

  • 1000.00 (default)

  • 1+000.00

  • 10+00.00

  • 1/000.00

Perform the following steps in order to change the station format.

  1. Press the "Station Format" soft key .

  1. Use the down arrow key and the up arrow key in order to choose the required format.

  1. When this has been completed and the other units are set, press the "OK" key in order to save the settings and return to the "Setup Menu – Installation" dialog.

  1. Press the "ESC" key in order to exit the "Setup Menu – Installation" dialog. The changes take effect immediately.

Caterpillar Information System:

777F Off-Highway Truck Engine Oil Level (Oil Renewal System) - Check - If Equipped
AccuGrade® GPS Using The CD550A Display (GPS/ATS/Sonic/Cross Slope) Modes of Operation
AccuGrade® GPS Using The CD550A Display (GPS/ATS/Sonic/Cross Slope) Guidance Terms
M325D and M330D Excavators Power Train Electronic Control System System Schematic
Installation of the Transmission Output Speed Sensor{3175} Installation of the Transmission Output Speed Sensor{3175}
Installation Of The Transmission Output Speed Sensor{3175} Installation Of The Transmission Output Speed Sensor{3175}
Installation Of The Transmission Output Speed Sensor{3141, 3175} Installation Of The Transmission Output Speed Sensor{3141, 3175}
3408E and 3412E Engines for Caterpillar Built Machines Alternator and Regulator
824H Wheel Dozer, 825H Soil Compactor and 826H Landfill Compactor Display and Camera - Clean - If Equipped with Work Area Vision System
AccuGrade® GPS Using The CD550A Display (GPS/ATS/Sonic/Cross Slope) Beeper
CB-334E and CB-335E Series II Paving Compactors Water Spray System Filter - Clean
2005/12/05 A Higher Setting for the Hoist Relief Valve Will Increase Hoist Pressure {5051, 5069, 5117}
797 Off-Highway Truck Engine Oil Level - Log Additions - If Equipped with the Oil Renewal System
420E, 430E, 432E, 434E, 442E and 444E Backhoe Loaders Fuel System Secondary Filter - Replace
The European Union Physical Agents (Vibration) Directive 2002/44/EC General Information - Background Information for the Directive on Vibration
583T Pipelayer Power Train Machine Preparation
420E, 430E, 432E, 434E, 442E and 444E Backhoe Loaders Hydraulic and Steering System Control Valve (Auxiliary)(Loader)
583T Pipelayer Power Train Transmission Lubrication Oil Pressure - Test
511 Track Feller Buncher, 521 Track Feller Buncher, 522 Track Feller Buncher and 532 Track Feller Buncher Machine Systems Swing Motor
1090 Series II, 1190 Series II, 1190T Series II and 1290T Series II Track Feller Bunchers Machine Systems Swing Brake
R1300G Series II Load Haul Dump Power Train MID 081 - CID 1926 - FMI 03
RM-500 Road Reclaimer/Soil Stabilizer Machine Systems Position Sensor (Front Steering) - Calibrate
R1300G Series II Load Haul Dump Power Train MID 081 - CID 1926 - FMI 05
511 Track Feller Buncher, 521 Track Feller Buncher, 522 Track Feller Buncher and 532 Track Feller Buncher Machine Systems Control Valve (Travel)
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.