Usage:
Fluid Spillage Containment
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "Tools And Shop Products Guide", NENG2500 for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
At operating temperature, the engine coolant is hot and under pressure. The radiator and all lines to heaters or the engine contain hot water or steam. Any contact can cause severe burns. Look at the sight gauge to check the coolant level. The coolant level should be in the green range. If necessary, remove the fill cap only after the engine has been stopped and the cap is cool enough to remove with your bare hand. Remove the cooling system fill cap slowly to relieve pressure. Cooling system condition contains alkali that can cause personal injury. Avoid contact with the skin and eyes and do not drink. Allow cooling system components to cool before draining. |
Start By:
a. remove fan guard
1. Remove four bolts (1) from fan shroud (2).
2. Reposition fan shroud (2) as shown, and loosen four bolts (3) from the fan.
3. Disconnect hose clamp (4) and the upper radiator hose.
4. Move the fan and the bolts against the radiator. Remove spacer (5) from the bolts and the fan. Remove fan (6).
NOTE: Install fan in the reverse order of removal.
End By:
a. install fan guard