Use of the 6V9130 Temperature Adapter Group{0776} Caterpillar


Use of the 6V9130 Temperature Adapter Group{0776}

Usage:

Introduction


6V9130 Temperature Adapter Group (1) 6V9129 Temperature Adapter. (2) 6V9131 K-Type Thermocouple Probe.

The 6V9129 Temperature Adapter (1) converts the input from a K-type thermocouple to 1mV/°C or 1mV/°F output for use with a Caterpillar 6V3030, 6V7070 or 6V7800 Digital Multimeter.

By plugging the adapter [with the 6V9131 K-type Thermocouple Probe (2) attached] into the VOLT and COMMON inputs of a digital multimeter, the user will have the measured temperature displayed on the multimeter.

Temperature adapter (1) operates with a 9-Volt battery and includes both cold junction compensation and two point linearization to ensure accuracy over the full operating range of the instrument.

Do not perform any procedure, outlined in this publication, or order any parts until you read and understand the information contained within.

Optional Accessories

The parts in the 6V9130 Temperature Adapter Group, and the available optional accessories, are shown below.


(1) 6V3073 Case. (2) 6V4094 Liner. (3) 8T0485 Block. (4) Form SEES5666 Decal (installs on lid of 6V3073 Case).


(5) 6V9129 Temperature Adapter. (6) Digital Multimeter (6V3030, 6V7070 or 6V7800). (7) 6V9131 Thermocouple Probe. (8) Multimeter Probes. (9) 8T0458 Thermocouple Wire.

The 8T0458 Thermocouple (9) is a fast acting probe for use in measuring air, oil or coolant temperature. The 6V9055 Exhaust Thermocouple Probe (10) can be used with the 6V9129 Temperature Adapter and a 6V3030, 6V7070 or 6V7800 Digital Multimeter to read exhaust temperature.

NOTE: The 8L4439 Exhaust Pyrometer Probe, with its J-type Thermocouple junction, cannot be used with, or adapted to, the 6V9129 Temperature Adapter.

Other new threaded K-type thermocouple probes are shown above. Probe lengths are given below.

8T0933 Thermocouple Probe, 25.4 mm (1.00") long.8T0934 Thermocouple Probe, 38.1 mm (1.50") long.8T0935 Thermocouple Probe, 63.5 mm (2.50") long.8T0936 Thermocouple Probe, 88.9 mm (3.50") long.

Safety Information

* Do not exceed a maximum of 500 Volts dc or rms at the thermocouple inputs.

------ WARNING! ------

One input of the thermocouple connector is connected to the multimeter COMMON input. If the thermocouple used with the temperature adapter is to be used to measure the temperature of a device that has a voltage with respect to the ground, the multimeter COMMON input must not be connected to ground. To do so may apply a direct short to the voltage of the device under test.

-------WARNING!-------

------ WARNING! ------

Always use care when taking measurements of hot and cold material.

-------WARNING!-------

6V9129 Temperature Adapter Specifications

Accurate at an Ambiant Temperature of 19°C to 25°C (66°F to 77°F)1.

Resolution: 0.1°C or (0.1°F) up to 199.9°C or (199.9°F).

1°C or (1°F) above 200°C or (200°F).

Setting time: 0.1 second.

Operating temperature: 0°C to +50°C (+32°F to 122°F).

Temperature Coefficient: 19°C to 25°C (66°F to 77°F), included in accuracy specification, 0°C to 19°C (32°F to 66°F) and 25°C to 50°C (77°F to 122°F), ±0.16°C/°C.

Thermocouple: Type K, probe or wire leads with miniature or subminiature male connector.

Battery Type: 9V (NEDA 1604D Carbon Zinc or 1604A Alkaline)

Battery Life: 75 hours (heavy duty): 100 hours (alkaline).

Output Short Circuit Duration: Indefinite (but batteries will be discharged).

Maximum Voltage at Thermocouple Input: 500 Vdc or RMS (common mode).

6V9131 Thermocouple Probe Specifications


(A) Sheath

Maximum Sheath (A) Temperature in Air: 1100°C (2012°F).

Maximum Handle Temperature: 200°C (390°F).

Error Limits: -20°C to +277°C ±1.1°C (-4°F to +530°F ±2°F),

+277°C to 1100°C (+530°F to 2012°F) ±0.375% of reading.

Response Time: Two seconds (to reach 63.2% of instantaneous temperature change.)

Maximum (Peak) Voltage at Probe Sheath: 250 Volts.

Plug Type: Industry standard, K-type miniature, color coded yellow.

Dimensions:

Handle; 102 ± 6 mm × 2.5 mm (4.00" ± 0.25" × 1.0" ± 0.1").

Probe; 100 ± 13 mm × 3 mm (4.00 ± 0.50" × 0.12").

Chord Length; 1220 ± 80 mm (48 ± 3").

8T0933, 8T0934, 8T0935 and 8T0936 Thermocouple Probe Specifications

Maximum Sheath Temperature in Air: 980°C (1800°F).

Maximum Lead (Connecting Wire) Temperature: 480°C (900°F).

Error Limits: -20°C to +277°C: ± 2.2°C (-4°F to +530°F: ± 3.9°F).

+277°C to +1100°C (+530°F to 2012°F): ± 0.75% of reading.

Response Time: Five seconds to reach 63.2% of instantaneous temperature change.

Plug Type: Industry Standard, K-type miniature, color coded yellow

These new probes can be used with the 6V9129 Temperature Adapter, a digital multimeter and the 5P2720, 5P2725 or 5P3591 Probe Seal Adapter Groups.

The above listed probes look similar to the thermistor thermometer probes except for the K-type thermocouple construction. The new probes are also designed to give a liquid tight seal when they are used with the probe seal adapters.

8T0458 Thermocouple Wire Specifications

Maximum Continuous Temperature: 200°C (390°F).

Error Limit: 0°C to +200°C; ± 1°C (32°F, ± 2°F).

Response Time: 0.7 second to reach 63.2% of instantaneous temperature change.

Plug Type: Industry standard, K-type miniature, color coded yellow.

Wire Length: 1.22 ±0.08 m (48 ± 3").

Maximum (Peak) Voltage at Thermocouple: 250 Volts.

6V9129 Temperature Adapter Operation

1. Battery Level Test - Before making temperature measurements, check the battery voltage level to be sure of proper operation of the unit.

* Connect 6V9129 Temperature Adapter (1) to multimeter (2) being used for temperature measurement. Adjust the multimeter to the 20 Vdc range.
* Put adapter ON/OFF/TEST switch to (3) to "TEST" position.

* If the reading displayed is less than 7.0 Vdc, install a new battery in adapter (1). See BATTERY REPLACEMENT FOR 6V9129 TEMPERATURE ADAPTER.

2. Adjust multimeter (2) to Vdc function as follows:

NOTE: The decimal point is not used when reading temperatures above 199.9°C or 199.9°F.

Example: A reading of 0.565 = 565°: 1.200 = 1200°.

NOTE: Due to temperature adapter internal limitations, the maximum temperature to be measured should not be more than 900°C (1652°F).

3. Plug the connector of the thermocouple probe or wire into the input connection of adapter (1). Do not force the connector into the adapter.

To ensure correct polarity for the thermocouple, the connector can only be installed one way. The narrow positive (+) terminal must plug into the left side (narrow slot) of the adapter input connector.

Use °C/°F Switch (4) to select the desired temperature reading.

4. Move ON/OFF/TEST Switch (3) to the ON position.

5. Put the thermocouple tip in contact with the area where temperature is to be measured. Allow a few seconds for the temperature reading on the multimeter to become stabilized.

6. Read the temperature displayed on the multimeter (2). When temperature measurement is complete, move ON/OFF/TEST Switch (3) to the OFF position to prolong battery life.

Battery Replacement for 6V9129 Temperature Adapter

1. Remove four screws (1). Separate the two halves of case (2), and remove battery (3).

2. Install a new heavy duty or alkaline 9 Volt battery.

3. Assemble the case; be sure that battery pad (4) and plugs (5) are in their correct position.

4. Install and tighten four screws (1).


NOTICE

Battery pad (4) must keep battery (3) separated from printed circuit board (PCB) (6), to prevent possible damage to the temperature adapter.


NOTE: When connecting a thermocouple connector to the temperature adapter make sure the thermocouple connector is correctly plugged into the adapter. The narrow positive (+) blade of the thermocouple connector must plug into the narrow positive socket (7) of temperature adapter connector (8).

Troubleshooting

If the temperature reading becomes erratic or is questionable, make sure the multimeter is working correctly. Then, check the battery voltage of the 6V9129 Temperature Adapter. See 6V9129 TEMPERATURE ADAPTER OPERATION.

If the test indicates correct operation of both parts, do the procedure that follows:

1. Inspect the thermocouple to make sure the wire is correctly connected to yellow thermocouple connector (1).

2. Remove two screws (2), and lift off cover (3).

* Make sure the thermocouple wire with the red insulation jacket is connected to the negative (-) blade terminal. [The negative (-) blade terminal is wider than the positive (+) blade terminal.] The thermocouple wire with the yellow insulation jacket should be connected to the position (+) blade terminal.

NOTE: Be sure the two wires are not touching (shorted) to each other.

3. Repair the connections if necessary, then install cover (3) and screws (2).

* If additional test, calibration or performance check information is needed, order a Service Manual for a Beckman Model TC-253 Temperature/Voltage Converter. Order Beckman Instructions FG3000-940-133 from the address given at the back of this instruction.

8T0458 Thermocouple Wire and/or 6V9131 Thermocouple Probe Repair

With normal use, 8T0458 Thermocouple Wire (1) and 6V9131 Thermocouple Probe (2) should not need service or adjustment. The only repair that can be made to either part is the replacement of thermocouple connectors (3) or (4).

Non-Warranty Repairs 6V9129 Temperature Adapter

Any out-of-warranty 6V9129 Temperature Adapter that is defective but repairable can be repaired by a Beckman Service Center. A repaired unit will carry a three (3) month warranty. Contact one of the Service Centers listed for their current non-warranty repair rates. Repairs made at the Beckman Factory Service Center are at a rate of $30.00* flat rate.

Beckman Instruments, Inc. Warranty

6V9129 Temperature Adapters are warranted in their entirety against any defects of material or workmanship which develop for any reason whatsoever, except abuse, within a period of one (1) year following the purchase of the unit by the original purchaser. This warranty is extended by Beckman Industries, Inc. (Beckman), only to the original purchaser or original user of the unit.

In the event a defect develops during the warranty period, Beckman will, at Beckman's election, repair or replace the unit with a new or reconditioned model of equivalent quality. In order to obtain performance of any obligation of Beckman under warranty, the original purchaser or original user must return the defective unit postage prepaid, along with the proper handling charge, to one of the Beckman Service Centers listed below.

In the event of replacement with a new or reconditioned model, the replacement unit will continue the warranty period of the original unit. Replacement units will be returned by air, typically with only two (2) working days turnaround at the Service Center.

Any implied warranties arising out of the sale of the 6V9129 Temperature Adapter including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to the above stated one (1) year period. Beckman shall not be liable for loss of the unit or other incidental or consequential damages, expenses, or economic loss.

USA Customers

Some states do not allow limitations on how long implied warranties last or the exclusion or limitations if incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Warranty Repair

6V9129 Temperature Adapters, less than one year old will be repaired under warranty for a handling charge of $3.00* in the continental USA and $12.00 elsewhere*, except for abuse. Any units claimed to be defective should be returned to one of the service centers listed. Warranty repair will be made typically within two (2) working days after receipt of a defective unit.


*Prices subject to change without notice.

Shipping Instructions

Units returned for repair or calibration should be shipped with the following information or items: Company name, customer's name, address, customer's telephone number, proof of purchase (warranty repair), a description of the problem encountered or service required, and the appropriate service charge. Service charges should be remitted in either the form of a check, money order or purchase order made payable to Beckman Instrument, Inc.

Service Centers for 6V9129 Only

Beckman Instruments, Inc.
Attn: Customer Service
210 Ranger Street
Brea, Ca. 92621
Telephone: (714) 993-8854
Telex: 06-78413 Relay to IPD BREA
TWX: 910-592-1260 Relay to IPD BREA

Beckman Industries, Ltd.
Components International
Queensway, Glenrothes, Fife
Scotland, KY7 5PU
United Kingdom

Caterpillar Information System:

Installation of 2W8511 Cam Loading Spring{1264} Installation of 2W8511 Cam Loading Spring{1264}
Using 6V9433 Crankshaft Removal Group{1000, 1202} Using 6V9433 Crankshaft Removal Group{1000, 1202}
Installation Of 4W6143 Sleeve{1201} Installation Of 4W6143 Sleeve{1201}
Use Of Preventive Maintenance Kits{7501} Use Of Preventive Maintenance Kits{7501}
Use And Repair Of The 6V7925 Fuel Rate Indicator{0782} Use And Repair Of The 6V7925 Fuel Rate Indicator{0782}
Replacement Of 5N1848, 5N1849 And 5N1850 A1 Module Regulator Assemblies{4467} Replacement Of 5N1848, 5N1849 And 5N1850 A1 Module Regulator Assemblies{4467}
Operation And Maintenance Of 6V9061 Pump Group{0623} Operation And Maintenance Of 6V9061 Pump Group{0623}
PREDELIVERY (REVISIT) PROCEDURE{7588, 7591, 7592} PREDELIVERY (REVISIT) PROCEDURE{7588, 7591, 7592}
Use Of Preventive Maintenance Kits{7501} Use Of Preventive Maintenance Kits{7501}
Use Of 6V4930 Battery Load Tester{0647} Use Of 6V4930 Battery Load Tester{0647}
Instructions For 3208 Engine Oil Filter Base Installation{1306} Instructions For 3208 Engine Oil Filter Base Installation{1306}
Instructions For 3208 Engine Tune-Up{1000} Instructions For 3208 Engine Tune-Up{1000}
Using the 8T900 AC/DC Clamp-On Ammeter{0651} Using the 8T900 AC/DC Clamp-On Ammeter{0651}
Using 8S2305, 9S228, And 6V9128 Rack Position Tool Groups{0782, 1250} Using 8S2305, 9S228, And 6V9128 Rack Position Tool Groups{0782, 1250}
Using 8T470 Thermistor Thermometer Group{0776} Using 8T470 Thermistor Thermometer Group{0776}
Installation of Water Pump Seal Group{1361} Installation of Water Pump Seal Group{1361}
Fuel System and Fuel Ratio Control Test Procedure{1264, 1278} Fuel System and Fuel Ratio Control Test Procedure{1264, 1278}
Crankshaft Cleaning Procedure{1202} Crankshaft Cleaning Procedure{1202}
Installation Of 7W1479 Magneto{1552} Installation Of 7W1479 Magneto{1552}
Installation of 7W2743 Speed Switch Assembly{7427} Installation of 7W2743 Speed Switch Assembly{7427}
"A Series" Governor And Air/Fuel Ratio Control Response And Low Power Test{0374} "A Series" Governor And Air/Fuel Ratio Control Response And Low Power Test{0374}
Installation of 0R2547 Remanufactured 3406 Truck Engine (Arrangement No. 4W2297){1000} Installation of 0R2547 Remanufactured 3406 Truck Engine (Arrangement No. 4W2297){1000}
Using The 6V9450 Engine Pressure Group{781} Using The 6V9450 Engine Pressure Group{781}
Installation of 3208 Remanufactured Engine (Natural Aspiration) for Industrial, Vehicular or Lift Truck Applications{1000} Installation of 3208 Remanufactured Engine (Natural Aspiration) for Industrial, Vehicular or Lift Truck Applications{1000}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.