SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Caterpillar


Generator Set Control Panel (If Equipped)

Usage:

The generator set control panel is located on top of the generator, and is equipped with the following controls and gauges.


CONTROL PANEL

1. Panel lights

2. Panel lights ON/OFF switch

3. Alternating current ammeter

4. Frequency meter

5. Alternating current voltmeter

6. Voltmeter/Ammeter phase selector

7. Engine control selector

8. Voltage level rheostat

9. Oil pressure gauge

10. Water temperature gauge

11. Shutdown indicators

12. Heat switch (if equipped)

13. Governor motor control switch (if engine is equipped with PSG governor)

Panel lights (1) are controlled by an ON/OFF switch (2).

An ammeter (3), frequency meter (4) and a voltmeter (5) show output of the generator. The voltmeter/ammeter phase selector switch (6) selects which phase (T1, T2, or T3) of generator output will be monitored on the ammeter (3) or the voltmeter (5).

The engine control switch (7) allows manual or automatic operation of the engine and generator set.

The engine control switch has four positions: MANUAL, AUTOMATIC, STOP AND OFF/RESET. Placing the control in MANUAL will start the engine.

In Automatic position, the Generator Set can be started when a customer supplied contact closes.

Both the Off and Stop positions stop the engine immediately, regardless of the cooldown timer. The cooldown timer is optional and functions only when the engine is controlled remotely, using the Automatic position of the engine control switch.

The voltage level rheostat (8) replaces the rheostat in the generator regulator assembly.

Gauge (9) indicates engine oil pressure and gauge (10) indicates engine water temperature.

If the engine has a malfunction, the panel will activate a shutdown relay to stop the engine. The shutdown lights (11) indicate if the fault has either oil pressure, water temperature, overspeed or an overcrank condition.

If the engine is equipped with glow plugs, they are controlled by an ON/OFF switch (12).

If engine is equipped with a PSG governor, governor motor switch (13) allows the operator to control the engine RPM from a panel.

Caterpillar Information System:

SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Generator Performance
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Voltage Connections
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Neutral Connections
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Generator Lead Connections
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Generator Identification
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Safety
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Model Views
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Foreword
D379, D398, D399 INDUSTRIAL AND GENERATOR SET ENGINES When Required
D379, D398, D399 INDUSTRIAL AND GENERATOR SET ENGINES Every 4000 Service Hours
D379, D398, D399 INDUSTRIAL AND GENERATOR SET ENGINES Every 2000 Service Hours
D379, D398, D399 INDUSTRIAL AND GENERATOR SET ENGINES Every 1000 Service Hours
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Generator Set Control Panel (If Equipped)
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Generator Set Control Panel (If Equipped)
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Oilfield Generator
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Single Unit Operation
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Parallel Operation
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Load Division-(Speed Droop)
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Circulating Currents
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Parallel Operation of Governors
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Parallel Operation of Governors
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Electronic (2301) Governor
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Stopping
SR 4 AND SRCR GENERATORS - OPERATION & MAINTENANCE Standby Electric Sets
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.