Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Caterpillar


Troubleshooting Diagnostic Codes

Usage:

C32 SXC
Diagnostic codes are associated with failed electrical components or circuits, that provide information to the Generator Set Control + Paralleling (GSC+P). Diagnostic codes are also associated with failed electrical components or circuits, that receive information from the GSC+P. The diagnostic code closely identifies the cause of the problem.

Each diagnostic code consists of the following items: a Component Identifier (CID), a Failure Mode Identifier (FMI) and "DIAG" indicator. These items are shown on the upper display. The diagnostic code indicator can be active or inactive. The CID identifies the component that has a problem. The FMI describes the nature of the diagnostic code. When the "DIAG" indicator is FLASHING, the diagnostic code is active. This means that the diagnostic code is present. When the "DIAG" indicator is ON CONTINUOUSLY, the diagnostic code is inactive and the CID FMI is recorded in the fault log. Refer to Systems Operation, "Fault Log Viewing OP1" in order to view the fault log. When the "DIAG" indicator is not showing, there are NO diagnostic codes that are detected or recorded. Service personnel interpret the identifiers in order to assist with troubleshooting.

When a diagnostic code occurs, the GSC+P FLASHES the "DIAG" indicator. The GSC+P determines the type of problem the code represents. There are two types of problems: an alarm fault and a shutdown fault. Then, the GSC+P FLASHES the corresponding fault alarm indicator or fault shutdown indicator. The CID FMI is immediately shown on the upper display when there is a shutdown fault. When there is an alarm fault, press the alarm codes key first. Then, the CID FMI is shown on the upper display.

The GSC+P has a fault log to help with troubleshooting of diagnostic codes. Inactive diagnostic codes (CID FMI) are recorded in the fault log for viewing at a later time. Also, the number of occurrences are totalled and the number of occurrences is shown on the upper display together with the CID and FMI. An active alarm fault becomes inactive when the problem is no longer occurring. Also, the engine control switch (ECS) should be turned to the OFF/RESET position for shutdown faults. The "DIAG" indicator is FLASHING when the problem is currently occurring. The "DIAG" indicator is ON CONTINUOUSLY when the problem occurred previously, but is inactive at the present time. Refer to Testing And Adjusting, "Fault Log Viewing OP1".

During troubleshooting, it is sometimes necessary to disconnect the harness connector from the GSC+P and diagnostic codes are created. Because of internal circuitry, the GSC+P recognizes this condition as a FMI 03 for FMI 02 for certain components. An FMI 03 or FMI 02 describes the voltage that is above normal. This fact is also used as an aid in the troubleshooting process. Clear these created diagnostic codes after the particular diagnostic code is corrected and the diagnostic code is cleared. The following diagnostic codes are recorded in a properly operating system when the harness connector is removed from the GSC+P.

CID 0100 FMI 02 - Pressure Sensor (Engine Oil)

CID 0110 FMI 02 - Temperature Sensor (Engine Coolant)

CID 0111 FMI 03 - Fluid Level Sensor (Engine Coolant)

CID 0175 FMI 03 - Temperature Sensor (Engine Oil)

CID 0190 FMI 03 - Speed Sensor (Engine)

CID 0336 FMI 02 - Switch (Engine Control)

An FMI 02 describes an incorrect signal.

Note: A CID 0111 FMI 03 and a CID 0175 FMI 03 will only be recorded if the machine is equipped with the proper sensors.

Clear diagnostic codes after the problem is investigated or the problem is corrected. This will avoid a confusion during a future service call. The "DIAG" indicator is OFF when all diagnostic codes are cleared from the fault log and no active diagnostic codes exist. Refer to Testing And Adjusting, "Fault Log Clearing OP4".

Diagnostic Codes

Table 1
Diagnostic Codes (1)
   
CID No. / FMI No.     Description    
CID 100 - Pressure Sensor (Engine Oil):    
FMI 2     Incorrect signal    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 110 - Temperature Sensor (Engine Coolant):    
FMI 2     Incorrect signal    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 111 - Fluid Level Sensor (Engine Coolant):    
FMI 3     Voltage above normal    
CID 168 - Electrical System Voltage:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 175 - Temperature Sensor (Engine Oil):    
FMI 2     Incorrect signal    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 190 - Speed Sensor (Engine):    
FMI 2     Incorrect signal    
FMI 3     Voltage above normal    
CID 248 - CAT Data Link:    
FMI 9     Abnormal update    
CID 268 - EMCP Electronic Control (Generator Set):    
FMI 2     Incorrect signal    
CID 269 - Sensor Power Supply:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 333 - Alarm Module Control:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 334 - Spare Output:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 336 - Switch (Engine Control):    
FMI 2     Undefined state    
CID 441 - Electronic Governor Relay:    
FMI 12     Failed component    
CID 442 - Generator Fault Relay:    
FMI 12     Failed component    
CID 443 - Crank Termination Relay:    
FMI 12     Failed component    
CID 444 - Starting Motor Relay:    
FMI 12     Failed component    
CID 445 - Run Relay:    
FMI 12     Failed component    
CID 446 - Air Shutoff Relay:    
FMI 12     Failed component    
CID 447 - Fuel Control Relay:    
FMI 12     Failed component    
CID 448 - Programmable Spare Relay:    
FMI 12     Failed component    
CID 475 - Relay Driver Module:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 500 - EMCP Electronic Control (Generator Set):    
FMI 12     Failed component    
CID 566 - Unexpected Shutdown:    
FMI 7     Improper mechanical response    
CID 590 - Engine Electronic Control Module:    
FMI 9     Abnormal update    
CID 770 - Customer Communication Module Data Link:    
FMI 9     Abnormal update    
CID 858 - Generator Close Breaker: (2)    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 859 - Kilowatt Level Output:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 1038 - Governor Adjust Analog Output:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 1167 - EPG Circuit Breaker:    
FMI 4     Voltage below normal    
CID 1168 - Dead Bus Sensor:    
FMI 3     Voltage above normal    
FMI 4     Voltage below normal    
CID 1169 - AC Transformer Box Sensor:    
FMI 2     Incorrect signal    
CID 1170 - Bus Transformer Box Sensor:    
FMI 2     Incorrect siganl    
FMI 4     Voltage below normal    
FMI 8     Abnormal signal    
CID 1178 - Pressure Sensor For Machine Overload Warning:    
FMI 3     Voltage above normal    
( 1 ) For troubleshooting, refer to the procedure with the same CID And FMI No.
( 2 ) Parallelling Applications Only

Example




Illustration 1g00615969

Upper Display Showing A CID 190 FMI 3 Diagnostic Code




Illustration 2g00608337

Upper Display Showing A CID 190 E FMI 3 Diagnostic Code

The "E" in the example shown in illustration 2 indicates that on EUI engines, the engine ECM has generated the diagnostic code. The EMCP II+P will display all diagnostic codes from the engine ECM. This assists the operator in diagnosing problems with the EUI engine. Refer to Troubleshooting, RENR9348 or Troubleshooting, RENR9968 for more information.

Caterpillar Information System:

Inspection and Reconditioning Procedures of Main Bearing Bores in Cylinder Blocks {1201, 1202, 1224, 1224} Inspection and Reconditioning Procedures of Main Bearing Bores in Cylinder Blocks {1201, 1202, 1224, 1224}
C9 Petroleum Engines Rocker Arm and Shaft - Install
320D and 323D Excavators Hydraulic System Swing Drive
G3600 Engines Fuel Control - Test
345D MHPU and 349D MHPU Mobile Hydraulic Power Units Machine System Fasteners
C9 Petroleum Engines Cylinder Block Cover - Remove and Install
G3600 Engines Sensor Signal (PWM) - Test
C9 Petroleum Engines Crankcase Breather - Remove and Install
C27 and C32 Engines for Caterpillar Built Machines Valve Actuator (Variable) - Install
C4.4 Generator Set Engines Injector Solenoid Circuit - Test
TH55-E70 and TH55-E90 Petroleum Transmissions Torque Converter - Assemble
TH55-E70 and TH55-E90 Petroleum Transmissions Torque Converter - Disassemble
2007/12/03 Improved Wiring for the Speed Control for the Electronic Governor {1408, 1417}
C9 Petroleum Engines Cylinder Head - Remove
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Display of Voltage or Current or Power Is Inaccurate
G3600 Engines Prelubrication - Test
Caterpillar Machine Fluids Recommendations Distillate Diesel Fuel
C9 Petroleum Engines Cylinder Head - Install
C175 Generator Sets After Starting Engine
C9 Petroleum Engines Engine Oil Pan - Remove and Install
G3500B Engines Prelubrication Pump Problem
G3600 Engines Air Starting Motor Problem
G3600 Engines Starting - Test
Electronic Modular Control Panel II+ Paralleling (EMCP II+P) Indicators of Alarm Module or Remote Annunciator Are Constantly Flashing
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.