Show/hide table
|
|
|
Illustration 1 | g00879777 |
Show/hide table
| Parking Brake - The parking brake switch will illuminate when the parking brake is applied. The light will remain illuminated if the parking brake switch is pulled up in order to release the brake and the propel lever is not in the STOP position. In order to move the machine, the propel lever must be in the STOP position before the parking brake is released. |
Show/hide table
|
|
|
Illustration 2 | g00751979 |
Show/hide table
| Alternator (1) - The lamp illuminates when the alternator is malfunctioning. If the indicator illuminates, stop the machine in a safe area. Investigate the cause of the problem. Check for a loose belt or a broken belt. Repair the problem before using the machine. |
Show/hide table
| Engine Oil Pressure (2) - The light illuminates when the engine oil pressure is low or there is a malfunction of the system. |
If the engine oil pressure light illuminates and there is an audible alarm, stop the engine. Investigate the cause of the alarm. Do not operate the machine until the cause of the alarm has been repaired.
Show/hide table
| Engine Coolant Temperature (3) - The light indicates overheating of the engine coolant or a malfunction of the system. |
If the light for the engine coolant temperature illuminates and there is an audible alarm, stop the machine in a convenient area. Investigate the cause of the alarm. Do not operate the machine until the cause of the alarm has been repaired.
Show/hide table
| Hydraulic Charge Pressure (4) - The light indicates low hydraulic charge pressure. |
If the light illuminates and an audible alarm sounds, stop the machine. If necessary, change the filter. Investigate the system for other problems if changing the filter does not correct the problem. Do not operate the machine until the problem has been repaired.
Show/hide table
| Hydraulic Oil Temperature (5) - The light will illuminate if the hydraulic oil in the hydraulic tank is too hot. |
If the light for the hydraulic temperature illuminates, stop the machine. Move the throttle switch to low idle. Allow the machine to idle for a few minutes. Resume using the machine if the temperature returns to the normal temperature. If the temperature remains above normal, stop the machine. Investigate the cause of the alarm. Do not operate the machine until the cause of the alarm has been repaired.