C27 Generator Set Caterpillar


Air Shutoff - Test

Usage:

C27 EGG



Illustration 1g01402506

Air shutoff with the valve mechanism in the OPEN position

Note: Do not start the engine. Ensure that the engine control is in the "OFF" position.

  1. Ensure that the valve mechanism is latched in the OPEN position. Turn on the power to the engine control panel. The valve mechanism should remain open. If the valve mechanism does not remain open, check the wiring for the air shutoff switches.

  1. With the power for the engine control panel in the ON position, activate the "EMERGENCY STOP" switch. If the valve mechanism closes, proceed to step 3. If the valve mechanism does not close, check the wiring for the air shutoff switch and check the wiring for the solenoids. Activate the "EMERGENCY STOP" switch again. When the valve mechanism closes, proceed to step 3.

  1. Reset the valve mechanism to the CLOSED position. Operate the engine normally. Ensure that the valve mechanism continues to be latched.

Refer to the Troubleshooting Guide, "Air Shutoff System" information in your Service Manual for further information about the electrical system for the air shutoff system.

Caterpillar Information System:

C18 Marine Auxiliary and Marine Generator Set Engines Engine Oil Pressure - Test
320D2 and 323D2 Excavators Machine Systems Specifications Boom Cylinder Lines
C32 Marine Engines Valve Mechanism Cover - Remove and Install
3516B Engine Vibration Damper - Remove and Install
2012/08/28 A New Aftercooler Cover, Base Assembly, and Mounting Hardware Are Used on Certain C18 Marine Engines {1063}
C27 Generator Set Model View Illustrations
2012/08/10 Clarification on the Bracket for Use with the Front Oil Cooler Bonnet on Certain 3500 Engines {0635, 1380}
C27 PET GEN SET Electric Power Generation and C27 KNOCKDOWN K Petroleum Power Train Package Maintenance Interval Schedule
C27 Generator Set Maintenance Interval Schedule - Standby
C18 Marine Auxiliary and Marine Generator Set Engines Engine Shutdown Occurrence
C27 PET GEN SET Electric Power Generation and C27 KNOCKDOWN K Petroleum Power Train Package Maintenance Interval Schedule
C27 Generator Set Maintenance Interval Schedule - Prime Power
G3500H 50Hz Generator Sets Flexible Coupling - Inspect
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Fuel Filter Differential Pressure - Check - Gas Fuel System
2012/08/07 New Thermostats Are Now Used for Jacket Water Heater on Certain Cat Gensets and Cat Engines {1383}
G3500H 50Hz Generator Sets Generator - Dry
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Hoses and Clamps - Inspect/Replace
PM3516 Power Modules Starting Motor - Inspect
3516B Engine Crankshaft Front Seal and Wear Sleeve - Install
3516B Engine Flywheel - Remove and Install
Reusability Guidelines for Single Tooth Master Links {0729, 4150, 4169, 4171} Reusability Guidelines for Single Tooth Master Links {0729, 4150, 4169, 4171}
3516B Engine Flywheel Housing - Remove
C18 Marine Engines Engine Stalls at Low RPM
3516B Engine Engine Oil Sequence Valves - Remove and Install
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.