Diagnostic Codes Table     | ||
---|---|---|
Code     | Conditions which Generate this Code     | System Response     |
268-2 Programmed Parameter Fault : Erratic, Intermittent, or Incorrect     | The engine's Electronic Control Module (ECM) detects that one or more of the programmable parameters have not been programmed.     | The ECM may use a default torque map or the ECM may limit the engine to low idle. The code is active only.     |
System configuration parameters are parameters that affect the emissions and the power of the engine. Default values for the parameters are programmed at the factory.
The Caterpillar Electronic Technician (ET) can be used to view certain parameters that can affect the operation of the engine. Cat ET can also be used to change certain parameters. There may be certain parameters that cannot be changed and there are some applications that do not allow any changes to the programmable monitoring system. The parameters are stored in the ECM. Some of the parameters are protected from unauthorized changes by passwords. Parameters that can be changed have a tattletale number. The tattletale number shows if a parameter has been changed.
Check Programmable Parameters (268-2)
If a programmable parameter has not been programmed, the ECM will generate a 268-2 Check Programmable Parameters diagnostic code. The programmable parameter that is not programmed will be listed under the code. The unprogrammed parameters will be set to default. Certain aspects of the engine's performance and engine monitoring may be affected.
If "Injector Trim" is displayed below a 268-2 diagnostic code on Caterpillar Electronic Technician (ET), refer to Troubleshooting, "Injector Trim File - Install".
Parameter Descriptions
"Equipment ID"
"Equipment ID" allows the customer to enter a description into the ECM in order to identify the machine. A maximum of 17 characters may be entered in the field. This parameter is only for reference by the customer. This parameter is not required.
"Engine Serial Number"
Program the "Engine Serial Number" to match the engine serial number that is stamped on the engine information plate. If the ECM is replaced, the engine serial number from the engine information plate must be programmed into the new ECM.
Note: When you are requesting factory passwords, always use the engine serial number that is programmed in the ECM.
"Rating Number"
The "Rating Number" corresponds to the selected set of performance maps for the application. This selected set of performance maps comes out of several unique sets of maps that are resident in the flash file.
"Top Engine Limit" (TEL)
Illustration 1 | g01750573 |
"TEL" is a parameter that defines the maximum allowable engine speed for maximum power. "TEL" can be programmed up to the maximum rated engine speed. "TEL" is defined along the engine's lug curve.
"Engine Accel. Rate"
"Engine Accel. Rate" determines the rate of change of the engine speed (acceleration or deceleration) during PTO operation. This rate of change is also used to achieve intermediate engine speed.
"FLS" (Full Load Setting)
"FLS" is a number that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate.
"FTS" (Full Torque Setting)
"FTS" is similar to "FLS".
"Air Shutoff"
"Air Shutoff" allows the ECM to be programmed for operation of an air shutoff system. If this parameter is programmed to "Installed", the ECM will activate the air shutoff solenoid in the event of an engine overspeed condition.
Note: If an engine overspeed condition occurs and "Air Shutoff" is programmed to "Enabled", the switched power to the ECM must be cycled and the air shutoff solenoid must be manually reset before the engine will restart.
System Configuration Parameters
System Configuration Parameters     | |||||
---|---|---|---|---|---|
Parameter     | Available Range or Options     | Default     | Required Password     | ||
ECM Identification Parameters     | |||||
"Equipment ID"     | 17 alphanumeric characters     | "NOT PROGRAMMED"     | None     | ||
"Engine Serial Number"     | 0XX00000 or XXX00000     | 0XX00000     | None     | ||
"ECM Serial Number"     | "Read Only" (1)     | ||||
"Personality Module Part Number"     | Software Dependent     | Read Only (1)     | |||
"Software Gp Release Date"     | Software Dependent     | Read Only (1)     | |||
Selected Engine Rating     | |||||
"Rating Number"     | Software Dependent     | Factory     | |||
"Rated Power"     | Software Dependent     | Read Only (1)     | |||
"Rated Peak Torque"     | Software Dependent     | Read Only (1)     | |||
"Top Engine Speed Range"     | Software Dependent     | Read Only (1)     | |||
"Test Spec"     | Software Dependent     | Read Only (1)     | |||
"Top Engine Limit"     | Rated Speed     | Read Only (1)     | |||
"Engine Acceleration Rate"     | 50 to 1000     | 50     | Read Only (1)     | ||
"Customer Password #1"     | 8 alphanumeric characters     | Blank     | Read Only (1)     | ||
"Customer Password #2"     | 8 alphanumeric characters     | Blank     | Read Only (1)     | ||
"FLS" (Full Load Setting)     | - 128 to 127     | 0     | Read Only (1)     | ||
"FTS" (Full Torque Setting)     | -128 to 127     | 0     | Read Only (1)     | ||
"Air Shutoff"     | "Enabled" "Disabled"     |
"Enabled"     | Read Only (1)     | ||
"Last Tool to change System Parameters"     | Read Only (1)     | ||||
"Total Tattletale"     | Read Only (1)     |
( 1 ) | The parameter can only be viewed. No changes are allowed. |
Parameters Worksheet
Note: A mistake in recording this information will result in incorrect passwords.
Engine Parameters     | |
---|---|
ECM Identification Parameters     | |
"Equipment ID"     |     |
"Engine Serial Number"     |     |
"ECM Serial Number"     |     |
"Software Gp Part Number"     |     |
"Personality Module Release Date"     |     |
Selected Engine Rating     | |
"Rating Number"     |     |
"Rated Power"     |     |
"Rated Peak Torque"     |     |
"Top Engine Speed Range"     |     |
"Test Spec"     |     |
"Top Engine Limit"     |     |
"Engine Acceleration Rate"     |     |
"Customer Password #1"     |     |
"Customer Password #2"     |     |
"FLS"     |     |
"FTS"     |     |
"Air Shutoff"     |     |
"Total Tattletale"     |     |
Information from Engine Information Plate     | |
"Engine Serial Number"     |     |
"FLS"     |     |
"FTS"     |     |
Note: Compare the FLS and the FTS from the ECM with the values that are listed on the engine information plate. Only change the FLS and the FTS because of a mechanical change in the engine. The use of the wrong parameters could cause damage to the engine. The use of the wrong parameters may also void the Caterpillar warranty.