Diesel Particulate Filter Temperature and Pressure Sensor
Show/hide table
Illustration 1 | g02994176 |
Show/hide table
Specification for 286-1240 Temperature and Pressure Sensor Gp | |||
Item | Qty | Part | Specification Description |
1 | - | - | Before assembly, apply Loctite C5A Copper Anti-Seize to the threads of the temperature and pressure sensor group.
Torque the temperature and pressure sensor group to |
- | - | - | Supply voltage is 4.75 to 5.25 VDC.
Output type is analog. |
Caterpillar Information System:
New Secondary Fuel Filter{1250, 1251, 1261, 1262} New Secondary Fuel Filter{1250, 1251, 1261, 1262}
C15 Engine for Combat and Tactical Vehicles Turbocharger
C15 On-highway Engine BrakeSaver Engine Oil Filter Base
3412, 3412C, and 3412E Generator Set Engines Acceleration Is Poor or Throttle Response Is Poor
325 VARIABLE UNDERCARRIAGE VH Undercarriage/VM Undercarriage Hydraulic System Sequence Valve (Travel Parking Brake) - Test and Adjust - VH Undercarriage
2008/09/01 A New Air Lines Group and New Software Groups Are Now Used {1071, 1901, 7620}
3412, 3412C, and 3412E Generator Set Engines Electronic Service Tool Does Not Communicate
320 Variable Gauge OEM Undercarriage Hydraulic System Travel Motor
3412, 3412C, and 3412E Generator Set Engines Service Meter Problem
Procedure for Cleaning Soot from the Engine after a Failure of the Diesel Particulate Filter (DPF) {1052, 1053, 1061, 1063, 1087, 108C, 108N} Procedure for Cleaning Soot from the Engine after a Failure of the Diesel Particulate Filter (DPF) {1052, 1053, 1061, 1063, 1087, 108C, 108N}
3512B Generator Set Engine CAN Data Link - Test
349E Excavator Machine System Specifications Track
3412, 3412C, and 3412E Generator Set Engines Engine Top Speed Is Not Obtained
C6.6 Marine Generator Set Coolant Temperature Sensor
New Secondary Fuel Filter{1261} New Secondary Fuel Filter{1261}
3512B Generator Set Engine Cat Data Link - Test
3512B Generator Set Engine Electrical Power Supply - Test
3412, 3412C, and 3412E Generator Set Engines Engine Misfires, Runs Rough or Is Unstable
2008/08/18 New Engine Software that Enables a Programmable High Idle Speed Is Available {1901, 1902}
3512B Generator Set Engine Emergency Stop - Test
3412, 3412C, and 3412E Generator Set Engines Engine Stalls Immediately After Starting
345D, 349D and 349D2 Excavators Reference Material
Replacing the Convection Jacket Water Heaters with the 325-6250 Jacket Water Heater Gp on 3500 Generator Set Engines{1361, 1383, 1408} Replacing the Convection Jacket Water Heaters with the 325-6250 Jacket Water Heater Gp on 3500 Generator Set Engines{1361, 1383, 1408}
3412, 3412C, and 3412E Generator Set Engines Engine Shutdown Is Intermittent