- Compact Wheel Loader
- 906K (S/N: L661-UP)
- 906M (S/N: H661-UP; Z661-UP)
- 907K (S/N: L771-UP)
- 907M (S/N: H771-UP; Z771-UP)
- 908K (S/N: L881-UP)
- 908M (S/N: H881-UP; Z881-UP)
- 906M (S/N: H661-UP; Z661-UP)
Introduction
The problem that is identified below does have a known permanent solution. Use the solution that is identified below.
Problem
On certain Compact Wheel Loaders, operators have reported a lack of response from the throttle pedal, inching pedal, and PCOR (motor pressure control). Operators have requested a need for a faster response from the drivetrain.
Solution
New software has been developed to address this issue. Carry out Service Letter , PS45077. If the service letter has already been completed, then only the primary software file requires updating.
Install the new 539-3691 Machine Software Gp. Following installation, the hydrostatic pump and implements will require calibration.
ET2017B should be used to reflash the machine.