D8T Track-Type Tractor Systems Caterpillar


Piston Pump (Fan Drive)

Usage:

D8T FMC
The fan pump adjusts fan speed in order to match the cooling demands of the system. The fan pump adjusts fan speed by adjusting oil flow to the fan motor. The flow of the fan pump is adjusted by the pump control valve.

The engine ECM receives input from the following sensors:

  • Hydraulic oil temperature sensor

  • Engine coolant temperature sensor

  • Engine intake air temperature sensor

  • Engine Speed

The engine ECM adjusts pump output by varying the amount of signal current that is sent to the solenoid on the pump control valve. Maximum signal current results in minimum pump output. Minimum signal current results in maximum controlled pump output. No signal current results in maximum mechanical pump output.

Fan Pump and Control Valve

Operation at Maximum Speed



Illustration 1g03513356
Fan Pump and Control Valve (Maximum Speed)
(1) Actuator Piston
(2) Swashplate
(3) Bias Spring
(4) Drive Shaft
(5) Fan Pump
(6) Piston and Barrel Assembly
(7) Case Drain Passage
(8) Output to Fan Motor
(9) Pin
(10) Plunger
(11) Spring
(12) Solenoid
(13) Adjustment Screw
(14) Spring
(15) Orifice
(16) Signal Passage
(17) Pump Control Spool
(18) Pressure Control Spool
(19) Adjustment Screw
(20) Pump Control Valve
(BB) Cutaway Section
(CC) Component Surface
(FF) Activated Components
(GG) Tank Pressure
(KK) High Pressure

When maximum calibrated fan speed is required, the engine ECM sends minimum signal current to solenoid (12). Plunger (10) blocks signal passage (16). The force of spring (14) plus the signal pressure holds pump control spool (17) downward.

When pump control spool (17) is held downward, the passage to actuator piston (1) is open to the case drain. The force of bias spring (3) moves swashplate (2) toward the maximum angle.

The pistons travel in and out of the barrel at the maximum distance. The piston fills to the maximum amount. The oil flows through output (8) to the fan motor causing the fan to rotate at the maximum speed.

Pressure control spool (18) limits the maximum mechanical pump pressure (high-pressure cutoff) of the oil that flows to the fan motor through output (8). If the output pressure overcomes spring (11), the pressure control spool moves upward. High-pressure oil is allowed to flow to actuator piston (1). The pump destrokes.

Operation at Minimum Speed



Illustration 2g03513376
Fan Pump and Control Valve (Minimum Fan Speed)
(1) Actuator Piston
(2) Swashplate
(3) Bias Spring
(4) Drive Shaft
(5) Fan Pump
(6) Piston and Barrel Assembly
(7) Case Drain Passage
(8) Output to Fan Motor
(9) Pin
(10) Plunger
(11) Spring
(12) Solenoid
(13) Adjustment Screw
(14) Spring
(15) Orifice
(16) Signal Passage
(17) Pump Control Spool
(18) Pressure Control Spool
(19) Adjustment Screw
(20) Pump Control Valve
(BB) Cutaway Section
(CC) Component Surface
(FF) Activated Components
(GG) Tank Pressure
(LL) First Pressure Reduction
(MM) Second Pressure Reduction

When the engine is first started or when the machine is working in a cold climate, the required fan speed for cooling is low. The ECM sends the maximum signal current to solenoid (12).

When a slower fan speed is required, the engine ECM increases the signal current to solenoid (12). Pin (9) pushes plunger (10) downward against spring (11). When the plunger moves downward, signal passage (16) is opened to the case drain. The pressure at the top of pump control spool (17) lowers. The pressure at the bottom of the pump control spool overcomes the force of spring (14). The spool shifts upward. This shift upwards allows pressurized oil to flow to actuator piston (1).

When oil flows into actuator piston (1), the force of bias spring (3) is overcome. Swashplate (2) moves toward the minimum angle until equilibrium is reached between the pressure in the actuator piston and the force of the bias spring.

The pistons travel in and out of the barrel for shorter distance. The pistons fill to a lower amount. A decreased amount of oil flows through output (8) to the fan motor. The decreased amount of oil flow to the fan motor causes the fan to rotate at slower speed.

Components of the Fan Pump and Control Valve

Actuator Piston (1) - When the pressure of the oil increases behind the actuator piston, the piston overcomes the force of bias spring (3). This force reduces the angle of swashplate (2).

Swashplate (2) - The angle of the swashplate controls the displacement of the pump. When the swashplate is at a maximum angle, the pistons move the maximum volume of oil in and out of the rotating barrel.

Bias Spring (3) - When oil acts on actuator piston (1), the angle of swashplate (2) is decreased. When there is no oil pressure at the actuator piston, the bias spring holds the swashplate at the maximum angle.

Drive Shaft (4) - The rotation of the pump is clockwise when the pump is viewed from the drive end. The piston and barrel assembly (6) is splined to the drive shaft. The piston and barrel assembly rotate when the drive shaft rotates.

Piston and Barrel Assembly (6) - The barrel contains nine pistons. The piston and barrel assembly rotate whenever the engine is running. The pistons move oil into the barrel and out of the barrel.

Case Drain Passage (7) - When solenoid (12) is de-energized, the oil at the top of actuator piston (1) flows around pressure control spool (18) and pump control spool (17). The oil then travels through case drain passage (7) to the hydraulic oil tank.

Output to Fan Motor (8) - When the piston and barrel rotate, pressurized oil flows to the fan motor from the output to the fan motor.

Pin (9) - This pin is part of solenoid (12). When the solenoid is energized, the pin pushes plunger (10).

Plunger (10) - Pin (9) pushes plunger (10) downward when solenoid (12) is energized.

Spring (11) - This spring reacts against pressure control spool (18) in response to plunger (10) moving downward.

Solenoid (12) - The solenoid receives input current from the engine ECM. When the solenoid receives maximum input current, pin (9) moves plunger (10) downward to the maximum distance. When minimum current is sent to the solenoid, spring (11) pushes plunger (10) fully upward.

Adjustment Screw (13) - The adjustment screw is used to decrease the spring pressure against pump control spool (17) or the adjustment screw is used to increase the spring pressure.

Spring (14) - This spring and the load sensing signal pushes pump control spool (17) downward. When some of the oil from the load sensing signal is allowed to flow around plunger (10), the pump control spool moves upward when the pressure on the other side of the pump control spool becomes greater than the sum of the force of the spring and the pressure from the load sensing signal.

Orifice (15) - This orifice allows some of the oil from the pump output to flow through pump control spool (17). This oil then flows through signal passage (16).

Signal Passage (16) - The signal passage allows oil to drain from the top side of pump control spool (17) to case drain passage (7). This action allows the pump control spool to move upward.

Pump Control Spool (17) - The load sensing signal and spring (14) apply pressure on the top of the pump control spool. Pump output pressure acts on the bottom of the pump control spool. The pump control spool shifts upward in order to allow oil to flow to actuator piston (1).

Pressure Control Spool (18) - The pressure control spool limits the maximum pressure of the output oil to the fan motor. When pump output pressure is high enough to overcome the force of spring (11), pressure control spool moves upward. High-pressure oil flows to actuator piston (1). The angle of the swashplate is reduced and the pump destrokes.

Adjustment Screw (19) - This adjustment screw is used to adjust the tension on spring (11). Increased tension on the spring causes plunger (10) to move less when the plunger is pushed by pin (9).

Caterpillar Information System:

2014/01/07 An Improvement to the Right Engine Enclosure Door Latch Is Now Used {1150, 7251, 7251}
D10T2 Track-Type Tractor Cooling System Coolant (ELC) - Change
2013/11/12 An Improved Fuel Filler Neck Tube As Is Now Used on Certain Compact Wheel Loaders {1273, 1273}
D6N LGP OEM Track-Type Tractor Hydraulic System General Information (Hydraulic System)
910K and 914K Compact Wheel Loaders Hydraulic Fan Speed - Test and Adjust
374F and 390F Excavators and 390F MHPU Mobile Hydraulic Power Unit Solenoid Valve (Switch Controlled) - Test
C4.4 Engines for Caterpillar Built Machines Turbocharger
D10T2 Track-Type Tractor Machine Systems Ripper Lift Cylinder - Remove and Install
C4.4 Engines for Caterpillar Built Machines Fuel Injection Pump
C4.4 Engines for Caterpillar Built Machines Fuel Filter Base - Twin Secondary Fuel Filter Base
623H Wheel Tractor-Scraper Rollover Protective Structure (ROPS) - Inspect
C4.4 and C7.1 Engines Fuel Pressure Problem
D10T2 Track-Type Tractor Cooling System Coolant Level - Check
D10T2 Track-Type Tractor Cooling System Coolant Sample (Level 2) - Obtain
836K Landfill Compactor, 834K Wheel Dozer and 988K Wheel Loader Power Train Power Train Oil Filter Bypass Valve - Remove and Install
D10T2 Track-Type Tractor Electronic Unit Injector - Inspect/Adjust
D7E Track-Type Tractor Track Adjuster and Recoil System - Check/Adjust
D8T Track-Type Tractor Systems Location of Components (Steering System)
D8T Track-Type Tractor General Information (Steering System)
D10T2 Track-Type Tractor Engine Air Precleaner - Clean
24 Motor Grader Engine Crankcase Breather - Clean
C15 and C18 Engines for Caterpillar Built Machines Valve Rocker Arm
992K Wheel Loader Systems Position Sensor (Lift Linkage, Tilt Linkage)
C13, C15, and C18 Tier 4 Final Engines Electronic Unit Injector Rocker Arm
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.