854K Wheel Dozer, and 992K and 993K Wheel Loaders Monitoring System Caterpillar


MID 052 - CID 0596 - FMI 09

Usage:

992K 880
Conditions Which Generate This Code:


Illustration 1g02693961

This diagnostic code is associated with the information from the Implement ECM to the Advisor. The information is sent via the Cat Data Link. The Cat Data Link is connected to two inputs of the Advisor.

The FMI 09 means that the Advisor has not received expected information from the Implement ECM.

The possible causes of this diagnostic code are listed:

  • The wires for the Cat Data Link to the Implement ECM are open or the wires are shorted.

  • The wrong software is installed on an ECM.

Note: The following test procedure may create other diagnostic codes. Ignore these diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0596 FMI 09 is active before performing this procedure.

Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS

  1. Verify that the following information is correct:

    • The part number of the software for the Implement ECM

    • The part number of the software for the Advisor

    • The part number of the Implement ECM

    • The part number of the Advisor

    Note: Consult your Caterpillar dealer for the correct part numbers of the software.

Expected Result:

All of the part numbers are correct.

Results:

  • YES - All of the part numbers are correct. Proceed to Test Step 2.

  • NO - One or more of the part numbers are not correct.

    Repair: Replace the incorrect ECM with an ECM that has the correct part number. Install the correct software. Refer to Testing and Adjusting, "Module - Replace" and Testing and Adjusting, "Module - Flash Program".

    STOP

Test Step 2. INSPECT THE HARNESS CONNECTIONS

  1. Turn the disconnect switch and the key start switch to the OFF position.

  2. Inspect all harness connections that are related to the Cat Data Link. Make sure that the connectors are clean and tight.

  3. Check the connectors for proper mating. Ensure that all the seals are present and in place.

  4. Check the harness for signs of damage or abrasion.

  5. Check the wires at the connector. Ensure that the wires are secured tightly into the connector. Take care not to pull the wire out of the connector.

  6. Check the exposed wires at the connectors for nicks or signs of abrasion.

  7. Check for moisture inside the connector.

  8. Check the connectors for dirty contacts or corroded contacts.

  9. Check each pin and each socket of the machine harness connectors. Ensure that the contacts are properly installed. The contacts should mate correctly when the two pieces of the connector are placed together.

Expected Result:

The machine harness connectors are tight and free of corrosion.

Results:

  • YES - The machine harness connectors are tight and free of corrosion. Proceed to Test Step 3.

  • NO - The machine harness connectors are in need of repair.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK FOR A SHORT CIRCUIT IN THE HARNESS

  1. Ensure that the disconnect switch and the key start switch remain in the OFF position.

  2. Disconnect the machine harness connectors from all electronic control modules that use the Cat Data Link.

  3. At the machine harness connector for the Messenger, measure the resistance between connector contact 4 (wire 893-GN(Green)) and all of the contacts that are used in the machine harness connector for the ECM. Perform the same measurements for 5 (wire 892-BR(Brown)).

Expected Result:

Each resistance measurement is greater than 5 ohms.

Results:

  • YES - Each of the resistance measurements is greater than 5 ohms. The harness circuit resistance is correct. Proceed to Test Step 4.

  • NO - One or more of the resistance measurements are less than 5 ohms. The machine harness has failed.

    Repair: There is a short between contact 8 (wire 893-GN(Green)) or contact 9 (wire 892-BR(Brown)) of the CAT Data Link and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.

    STOP

Test Step 4. CHECK FOR AN OPEN CIRCUIT

  1. Ensure that the disconnect switch and the key start switch remain in the OFF position.

  2. All related electronic control modules remain disconnected from the machine harness.

  3. Measure the resistance between connector contact J1-20 (wire 893-GN(Green)) of the Implement ECM and connector contact 4 (wire 893-GN(Green)) of the Messenger.

  4. Measure the resistance between connector contact J1-20 (wire 892-BR(Brown)) of the Implement ECM and connector contact 5 (wire 892-BR(Brown)) of the Messenger.

Expected Result:

The resistance is less than 5 ohms.

Results:

  • YES - The resistance is less than 5 ohms. The Cat Data Link circuit in the machine harness is correct. Proceed to Test Step 5.

  • NO - The resistance is greater than 5 ohms. The machine harness has failed.

    Repair: The Cat Data Link circuit is open in the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 5. CHECK IF THE DIAGNOSTIC CODE REMAINS

  1. Inspect the contacts of the harness connectors and clean the contacts.

  2. Reconnect all harness connectors.

  3. Turn the disconnect switch and the key start switch to the ON position.

  4. Operate the machine.

  5. Check the status of the CID 0596 FMI 09.

Expected Result:

The CID 0596 FMI 09 is active.

Results:

  • YES - The CID 0596 FMI 09 is active. The diagnostic code has not been corrected. The ECM may have failed.

    Repair: An ECM failure is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. Refer to Testing and Adjusting, "Module - Replace".

    STOP

  • NO - The CID 0596 FMI 09 is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

854K Wheel Dozer, and 992K and 993K Wheel Loaders Monitoring System MID 052 - CID 0800 - FMI 09
992K Wheel Loader and 854K Wheel Dozer Power Train Input Transfer Gear And Output Transfer Gear Lubrication
992K Wheel Loader and 854K Wheel Dozer Power Train Output Transfer Gears
992K Wheel Loader and 854K Wheel Dozer Power Train Input Transfer Gears
992K Wheel Loader and 854K Wheel Dozer Power Train Transmission Planetary
950K and 962K Wheel Loaders Power Train Backup Alarm Always On
Installation of the Variable Pitch, Angle, and Tilt Blade with or without Blade Slope Assist on a D6N Track-Type Tractor {6052, 6060, 6063, 6701} Installation of the Variable Pitch, Angle, and Tilt Blade with or without Blade Slope Assist on a D6N Track-Type Tractor {6052, 6060, 6063, 6701}
Proper Cleaning Procedure for Inspection of the Turbocharger Housing{1052} Proper Cleaning Procedure for Inspection of the Turbocharger Housing{1052}
950K and 962K Wheel Loaders Power Train Backup Alarm Always Off
854K Wheel Dozer Electrohydraulic System Event Code List
854K Wheel Dozer Electrohydraulic System Connector Locations
992K Wheel Loader and 854K Wheel Dozer Power Train Transmission Hydraulic Control Operation
992K Wheel Loader and 854K Wheel Dozer Power Train Differential
854K Wheel Dozer, and 992K and 993K Wheel Loaders Monitoring System MID 052 - CID 0590 - FMI 09
950K Wheel Loader and 962K Wheel Loader Steering System Piston Pump (Steering) High Pressure Stall - Test and Adjust
992K Wheel Loader and 854K Wheel Dozer Power Train Final Drive and Wheel
992K Wheel Loader and 854K Wheel Dozer Power Train Axle Oil Cooler
C32 LRC Engine for Track-Type Tractors Electrical Connectors
854K Wheel Dozer, and 992K and 993K Wheel Loaders Monitoring System MID 052 - CID 0296 - FMI 09
2011/08/24 New Monitor Software with Updated Language Packages Is Now Available for Certain D8T Track-Type Tractors {7490, 7620}
854K Wheel Dozer, and 992K and 993K Wheel Loaders Monitoring System MID 052 - CID 2448 - FMI 09
992K Wheel Loader and 854K Wheel Dozer Power Train Oil Coolers and Cooling System Operation
854K Wheel Dozer Electrohydraulic System MID 082 - CID 0767 - FMI 08
992K Wheel Loader Electrohydraulic System MID 082 - CID 2659 - FMI 04
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.