D6N Track-Type Tractor Caterpillar


MID 039 - CID 2204 - FMI 13

Usage:

D6N LGP PBA
Conditions Which Generate This Code:

This diagnostic code is recorded when the Machine ECM determines that the Auxiliary Lever #1 Position Sensor requires calibration. This diagnostic code will only appear when the Machine ECM has been replaced or new software has been flashed into the Machine ECM.

Test Step 1. CALIBRATE THE AUXILIARY LEVER #1 POSITION SENSOR

  1. Perform the calibration procedure for the sensor. See the Testing and Adjusting, UENR0057, "Implement Operator Control - Calibration" procedure.

Expected Result:

The calibration procedure for the sensor was performed successfully.

Results:

  • YES - The calibration procedure for the sensor was performed successfully. Resume normal machine operationSTOP

  • NO - The calibration procedure for the sensor was not performed successfully.

    Repair: Repeat the calibration procedure for the sensor. See the Testing and Adjusting, UENR0057, "Implement Operator Control - Calibration" procedure.

    STOP

Back to top