Removal Procedure
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Show/hide table
|
NOTICE |
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
|
- Drain the coolant from the cooling system into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant (ELC) - Change".
Show/hide table
|
|
|
Illustration 1 | g01452568 |
Show/hide table
|
|
|
Illustration 2 | g01452571 |
- Remove upper grill (1). Remove bolts (3). Position lower grill (2) to the side.
Show/hide table
|
|
|
Illustration 3 | g01452570 |
- Remove shields (4) .
Show/hide table
|
|
|
Illustration 4 | g01442643 |
- Disconnect hose assembly (8). Remove bolts (10) and position elbow assembly (9) out of the way. Remove bolts (5) and (7). Remove housing assembly (6) .
Show/hide table
|
|
|
Illustration 5 | g01442645 |
- Remove O-ring seal (11), O-ring seals (12), water temperature regulators (13), and lip seals (14) from housing assembly (6) .