Illustration 1 | g01277724 |
(1) Port T (2) Port C (3) Port P |
(4) Torque for installing the solenoid valve ... 24 ± 3 N·m (18 ± 2 lb ft)
(5) Torque for the nut ... 5.3 ± 1.5 N·m (47.0 ± 13.0 lb in)
Flow of SAE 10 oil from port P to port C at 900 kPa (130 psi) pressure drop and 38 °C (100 °F) ... 15.1 L/min (4.0 US gpm)
Flow of SAE 10 oil from port C to port T at 690 kPa (100 psi) pressure drop and 38 °C (100 °F) ... 15.1 L/min (4.0 US gpm)
Temperature range ... −40 to 120° C (−40 to 250° F)
Operating pressure rating ... 20700 kPa (3000 psi)
Maximum pressure rating ... 20700 kPa (3000 psi)
Nominal coil voltage ... 24 VDC
Minimum coil voltage at 20700 kPa (3000 psi) pressure and 121°C (250°F) ... 20.4 VDC
Maximum coil voltage at 20700 kPa (3000 psi) pressure and 121°C (250°F) ... 27.6 VDC
Coil resistance at 25 ± 5° C (77 ± 10° F) ... 35 ± 0.5 Ohms