Low Water Temperature Alarm Switch
Illustration 1 | g01017808 |
(1) Nut
- Torque ... 52.5 ± 7.5 N·m (39 ± 6 lb ft)
Operating temperature range ... -40 to 150 °C (-40 to 302 °F)
Actuation temperature to open ... 27° ± 3 °C (80° ± 5 °F)
Minimum deactuation temperature from the open position to the closed position ... 20 °C (68 °F)
Contact position below the deactuation temperature ... Normally closed
High Inlet Air Temperature Shutdown Switch
Illustration 2 | g01017878 |
(2) Nut
- Torque ... 82 ± 8 N·m (60 ± 6 lb ft)
Operating temperature range ... -40 to 150 °C (-40 to 302 °F)
Actuation temperature to open ... 68° ± 2 °C (155° ± 3 °F)
Minimum deactuation temperature from the open position to the closed position ... 59 °C (139 °F)
Contact position below the deactuation temperature ... Normally closed
High Inlet Air Temperature Alarm Switch
Illustration 3 | g01017911 |
(3) Nut
- Torque ... 82 ± 8 N·m (60 ± 6 lb ft)
Operating temperature range ... -40 to 150 °C (-40 to 302 °F)
Actuation temperature to open ... 66° ± 1.7 °C (150 ° ± 3 °F)
Minimum deactuation temperature from the open position to the closed position ... 56 °C (133 °F)
Contact position below the deactuation temperature ... Normally closed