G3406 Engines Caterpillar


Temperature Switch

Usage:

G3406 1RK

Low Water Temperature Alarm Switch




Illustration 1g01017808

(1) Nut

Torque ... 52.5 ± 7.5 N·m (39 ± 6 lb ft)

Operating temperature range ... -40 to 150 °C (-40 to 302 °F)

Actuation temperature to open ... 27° ± 3 °C (80° ± 5 °F)

Minimum deactuation temperature from the open position to the closed position ... 20 °C (68 °F)

Contact position below the deactuation temperature ... Normally closed

High Inlet Air Temperature Shutdown Switch




Illustration 2g01017878

(2) Nut

Torque ... 82 ± 8 N·m (60 ± 6 lb ft)

Operating temperature range ... -40 to 150 °C (-40 to 302 °F)

Actuation temperature to open ... 68° ± 2 °C (155° ± 3 °F)

Minimum deactuation temperature from the open position to the closed position ... 59 °C (139 °F)

Contact position below the deactuation temperature ... Normally closed

High Inlet Air Temperature Alarm Switch




Illustration 3g01017911

(3) Nut

Torque ... 82 ± 8 N·m (60 ± 6 lb ft)

Operating temperature range ... -40 to 150 °C (-40 to 302 °F)

Actuation temperature to open ... 66° ± 1.7 °C (150 ° ± 3 °F)

Minimum deactuation temperature from the open position to the closed position ... 56 °C (133 °F)

Contact position below the deactuation temperature ... Normally closed