Note: If the parameters that are protected with the factory passwords are changed, the Caterpillar warranty may be voided.
The engine serial number should be programmed to match the engine information plate. The serial number is not programmed on a new ECM.
Fuel Ratio Control (FRC) Offset
The ECM determines a value that is based on the atmospheric pressure. The value is used to adjust the fuel ratio control. This will control the exhaust while the engine accelerates. An offset value of ± 25 may be used to adjust for customer preference, fuel quality or other factors that affect engine performance.
Note: This parameter may not be available on all applications.
This parameter is used to set engine power. A Factory Password is required to change this setting.
Minimum | Default | Maximum |
Minimum Rack | Engine Dependent | Engine Dependent |
The parameter defines the lowest rpm level.
Minimum | Default | Maximum |
300 rpm | 600 rpm | 900 rpm |
This parameter defines the engine rpm level when the Engine Control Switch (ECS) is placed in the STOP position.
Minimum | Default | Maximum |
300 rpm | 600 rpm | 1600 rpm |
This parameter defines engine operation at the cooldown speed. Programming this parameter to 0 will disable this function.
Minimum | Default | Maximum |
0 minutes | 5 minutes | 30 minutes |
This parameter sets the engine prelubrication timeout period. Programming this parameter to 0 will disable this function.
Minimum | Default | Maximum |
0 seconds | 0 seconds | 210 seconds |
The crank duration determines when the starting motors will be energized. The crank duration determines when the starting motors will be disengaged. Programming this parameter to 0 will prevent the ECM from engaging the starting motors.
Minimum | Default | Maximum |
0 seconds | 0 seconds | 60 seconds |
This parameter is the total number of crank cycles that can be performed.
Minimum | Default | Maximum |
0 | 0 | 10 |
This parameter determines when the starting motor will disengage.
Minimum | Default | Maximum |
100 rpm | 400 rpm | 500 rpm |
Programming the parameter to "OFF" will disable the air shutoff. This parameter should be programmed to "OFF" if the function is not being used or installed on this engine. This will prevent diagnostics from being logged.
Note: This parameter can only be read from the secondary ECM.
Minimum | Default | Maximum |
DISABLED | ENABLED | ENABLED |