Illustration 1 | g01569121 |
Illustration 2 | g01156917 |
Typical solenoid connections |
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25 °C (77 °F)
- Speed ... 3638 ± 413 rpm
- Current ... 90 ± 16 Amp
- Voltage ... 23 VDC
- Current ... 90 ± 16 Amp
(A) Clearance between the pinion and the housing ... 1.02 ± 0.76 mm (0.040 ± 0.030 inch)
Note: A maximum of three cable terminals or wire terminals may be used with the battery terminal nut (1) . A maximum of two of the cable terminals may be equal to or greater than 0 AWG.
(1) Final installation torque for the battery terminal nut ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(2) Final installation torque for the ground terminal nuts ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(3) Final installation torque for the nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Note: The switch terminal must be insulated with heat shrink tubing. Do not use molded terminals.
(4) Final installation torque for the switch terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Note: The internal Torx screw must be held during tightening or loosening of the motor terminal nut (5) .
(5) Final installation torque for the motor terminal nut ... 14.7 ± 3.4 N·m (130 ± 30 lb in)
(6) Final installation torque for the bolt for the motor frame terminal ... 8 ± 3 N·m (70 ± 27 lb in)
Solenoid assembly
Current draw at 20 V and 25 °C (77 °F)
- Pull-in windings ... 36 Amp
- Hold-in windings ... 6 Amp
- Maximum rated current ... 750 Amp
- Hold-in windings ... 6 Amp