Illustration 1 | g00110215 |
(1) Manual reset button for the circuit breaker
(2) Maintenance indicator lamp (3) Diagnostic lamp (4) Warning lamp (5) Auto circuit breaker reset (6) Maintenance clear switch (7) Emergency stop button (8) Service hour meter (9) Start switch |
The control panel that is listed as standard equipment for the 3406E Marine Engine has the following features:
- Manual reset button for the circuit breaker
- Maintenance indicator lamp
- Diagnostic lamp
- Warning lamp
- Auto circuit breaker reset
- Maintenance clear switch
- Emergency stop button
- Service hour meter
- Start switch
The enclosure is mounted on the service side of the engine in a remote location.
Manual Reset Button for the Circuit Breaker (1) (15 amp breaker) - There are two circuit breaker reset buttons that are located within the control panel: auto circuit breaker reset (3 amp) (5) and manual reset button for the circuit breaker (15 amp). Check the circuit breaker reset button if there is a total loss of electrical power to the engine.
Maintenance Indicator Lamp (2) - This lamp will flash when scheduled maintenance needs to be performed. Refer to the Operation and Maintenance Manual for more information on the proper maintenance intervals.
Diagnostic Lamp (3) - This lamp will flash when a diagnostic code has been generated by the Electronic Control Module (ECM). The active diagnostic code will flash.
Warning Lamp (4) - This lamp will flash when a critical condition has occurred such as low oil pressure or high coolant temperature.
Maintenance Clear Switch (6) - The maintenance clear switch is pushed after the appropriate maintenance is performed. Push the maintenance clear switch in order to clear the maintenance indicator lamp.
Emergency Stop Button (7) - The OUT position is for normal engine operation. Once the emergency stop button is pushed to the IN position, the emergency stop button will be locked. The engine will shut down via a shutdown signal to the ECM. The ECM will remain on. When the emergency stop button is pushed to the IN position, the start switch is locked out. The start switch will not energize the starting motor magnetic switch. Turn the emergency stop button clockwise in order to release and allow start-up.
Service Hour Meter (8) - The service hour meter monitors the service hours of engine. The service hour meter will operate only when the engine is running.
Start Switch (9) - The start switch has three positions: OFF, RUN and START. When the start switch is turned clockwise to the RUN position, the lamps will flash for five seconds during the system test. The lamps will then shut off. In the RUN position, the ECM and electronic systems are powered up.
When the switch is turned to the START position, the starting motor magnetic switch is energized. The electric starting motor is engaged. The starting motor will continue to crank while the start switch is held in the START position. The start switch is spring loaded in order to return to the RUN position when the start switch is released. The engine may be shut down by turning the start switch to the OFF position. This mode of shutdown removes power to the ECM.