14L Motor Grader Implement Electronic Control System Caterpillar


MID 082 - CID 2172 - FMI 03

Usage:

14L B94
Conditions Which Generate This Code:


Illustration 1g01270535
Articulate Right Solenoid connections

This diagnostic code is associated with the articulate right solenoid. The FMI 03 means that the Implement ECM has determined that the voltage of the solenoid circuit is above normal.

The Implement ECM provides a PWM output signal to the solenoid in order to provide proportional control of the solenoid. The ECM will vary the electrical current of the PWM output signal based on the input command that is received from the articulation lever position sensor that is located in the left joystick assembly.

Conditions that can cause this diagnostic code are listed:

  • The energize circuit of the solenoid is shorted to another voltage source.

  • The ECM has failed. This is unlikely.

Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

Note: The resistance of the solenoid coil should be 8.7 ± .4Ω at 25 °C (77.0 °F).

Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT

  1. Turn the key start switch and the disconnect switch to the OFF position.

  2. Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 and J2 from the ECM.

  3. At the machine harness ECM connector J1, measure the resistance from contact J1-52 (wire K788-GY(Grey)) to all J1 and J2 contacts that are used on the ECM connectors.

Expected Result:

Each resistance measurement is greater than 5kΩ.

Results:

  • OK. - Each resistance measurement is greater than 5kΩ. The machine harness is correct. Proceed to Test Step 2.

  • NOT OK. - Each resistance measurement is not greater than 5kΩ. There is a short in the machine harness. The short is between wire K788-GY(Grey) and the circuit that has a low resistance measurement.

    Repair: Refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test" for more information on finding and correcting a short circuit. Repair the machine harness or replace the machine harness.

    STOP

Test Step 2. CHECK THE OPERATION OF THE ECM

The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.

  1. At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire K788-GY(Grey) and socket at contact J1-52 from the harness connector.

  2. Reconnect the machine harness J1 and J2 connectors to the ECM.

  3. Turn the disconnect switch and the key start switch to the ON position.

  4. Observe the status of the active CID 2172 FMI 03 diagnostic code.

Expected Result:

The CID 2172 FMI 03 diagnostic code is no longer active. A CID 2172 FMI 05 diagnostic code is now active.

Results:

  • YES. - The CID 2172 FMI 03 diagnostic code is no longer active. A CID 2172 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit. Reinstall the disconnected solenoid energize wire back into the correct space in the ECM connector before proceeding to the next test step. Proceed to Test Step 3.

  • NO. - The CID 2172 FMI 03 diagnostic code remains active. The status of the active diagnostic code did not change when the solenoid energize wire was disconnected from the ECM.

    Repair: The ECM has not responded correctly to the open condition in the solenoid circuit. The operation of the ECM is not correct.

    Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  2. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the sensor circuit.

  3. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are completely fastened.

  4. Turn the disconnect switch and the key start switch to the ON position.

  5. Operate the machine.

  6. Determine if the CID 2172 FMI 03 diagnostic code is active.

Expected Result:

The CID CID 2172 FMI 03 diagnostic code is active.

Results:

  • YES. - The CID 2172 FMI 03 diagnostic code is active.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.

    If the problem remains, the ECM may have failed. This is unlikely because the ECM detected the open circuit condition in the solenoid circuit and activated the FMI 05 diagnostic code when the solenoid energize wire was disconnected.

    Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.

    Prior to replacing an ECM, always contact your dealership's Technical Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO. - The CID 2172 FMI 03 code is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

14L Motor Grader Implement Electronic Control System MID 082 - CID 2171 - FMI 13
725C2, 730C, 730C EJECTOR, 730C2 and 730C2 EJECTOR Articulated Trucks Interaxle Lock Speed Is Mismatched
14L Motor Grader Implement Electronic Control System MID 082 - CID 2171 - FMI 06
14L Motor Grader Implement Electronic Control System MID 082 - CID 2171 - FMI 05
14L Motor Grader Implement Electronic Control System MID 082 - CID 2171 - FMI 03
14L Motor Grader Implement Electronic Control System MID 082 - CID 2170 - FMI 13
14L Motor Grader Implement Electronic Control System MID 082 - CID 2170 - FMI 06
14L Motor Grader Implement Electronic Control System MID 082 - CID 2170 - FMI 05
14L Motor Grader Implement Electronic Control System MID 082 - CID 2170 - FMI 03
14L Motor Grader Implement Electronic Control System MID 082 - CID 2169 - FMI 13
14L Motor Grader Implement Electronic Control System MID 082 - CID 2169 - FMI 06
14L Motor Grader Implement Electronic Control System MID 082 - CID 2169 - FMI 05
14L Motor Grader Implement Electronic Control System MID 082 - CID 2172 - FMI 05
14L Motor Grader Implement Electronic Control System MID 082 - CID 2172 - FMI 06
14L Motor Grader Implement Electronic Control System MID 082 - CID 2172 - FMI 13
14L Motor Grader Implement Electronic Control System MID 082 - CID 2173 - FMI 03
14L Motor Grader Implement Electronic Control System MID 082 - CID 2173 - FMI 05
14L Motor Grader Implement Electronic Control System MID 082 - CID 2173 - FMI 06
14L Motor Grader Implement Electronic Control System MID 082 - CID 2173 - FMI 13
725C2, 730C, 730C EJECTOR, 730C2 and 730C2 EJECTOR Articulated Trucks Interaxle Lock Supply Pressure Is High
826K Landfill Compactor, 825K Soil Compactor and 824K Wheel Dozer Machine Systems Parking Brake Actuator - Remove and Install
Post Factory Installation of the Rear Radar on 834K Wheel Dozers and 988K Wheel Loaders {7347} Post Factory Installation of the Rear Radar on 834K Wheel Dozers and 988K Wheel Loaders {7347}
725C Articulated Truck Electronic Control (Diesel Exhaust Fluid) - Remove and Install
826K Landfill Compactor, 825K Soil Compactor and 824K Wheel Dozer Power Train Front Guard - Remove and Install
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.