Usage:
6V0927 (24V), 6V0885 (24V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 6950 ± 1650 rpm
Current draw ... 115 ± 25A
Voltage ... 23V
Clearance between pinion and housing (pinion clearance) ... 9.1 mm (.36 in)
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Torque for screws holding nose housing to lever housing ... 20.3 ± 2.7 N·m (15 ± 2 lb ft)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull-in windings at 20V ... 49.3 ± 3.3A
Hold-in windings at 20V ... 6.8A maximum
Illustration 1
Illustration 2
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction ... Clockwise
No Load conditions at 25°C (77°F)
Minimum speed with no load ... 6900 ± 1800 rpm
Maximum current with no load ... 127.55 ± 27.5 amp
Voltage ... 11V
(1) Battery terminal
A maximum of three cable or wire terminals should be between the nuts.
Tighten the nut on the battery terminal to the following torque ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Ground terminal
Tighten the nut on the ground terminal to the following torque ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(3) Ground terminal
Tighten the nut on the ground terminal to the following torque ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Motor terminal
Tighten the nut on the motor terminal to the following torque ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(5) Switch terminal
The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals.
Tighten the nut on the switch terminal to the following torque ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(6) Motor frame terminal
Tighten the nut on the motor frame terminal to the following torque ... 8 ± 3 N·m (71 ± 27 lb in)
Solenoid
Current draw at 10 V and 25°C (77°F)
Pull-in windings ... 92.5 ± 7.5 Amp
Hold-in windings ... 23 Amp maximum
8C3644 (24V), 8C3449 (24V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 7643 ± 1683 rpm
Current draw ... 67.5 ± 7.5A
Voltage ... 23V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Torque for motor frame terminal ... 8 ± 3 N·m (70 ± 26 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull-in windings at 20V ... 56.5 ± 4.5A
Hold-in windings at 20V ... 14.6A
7T0794 (24V), 7T0795 (24V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 5500 rpm minimum
Current draw ... 140A maximum
Voltage ... 24V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull-in windings at 24V ... 51A
Hold-in windings at 24V ... 7A