Required Tools | |||
---|---|---|---|
Tool | Part Number | Part Description | Qty |
A | FT-2515 | Guide Bolt | 2 |
B | 138-7575 | Link Bracket | 2 |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat products. Dispose of all fluids according to local regulations and mandates. |
Personal injury can result from contact with refrigerant. This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system. Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury. Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant. Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting. Personal injury or death can result from inhaling refrigerant through a lit cigarette. Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death. Do not smoke when servicing air conditioners or wherever refrigerant gas may be present. Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen. |
- Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. . Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Show/hide table
Illustration 1 g01302310 - Remove bolts (1).
Show/hide table
Illustration 2 g01302312 - Install Tooling (A). Remove bolts (2).
Show/hide table
Illustration 3 g01302315 - Install Tooling (B) and a suitable lifting device to grill (3).
- Remove Tooling (A). Remove grill (3). The weight of grill (3) is approximately
25 kg (55 lb) .Show/hide tableIllustration 4 g01302317 - Disconnect hose assemblies (5). Remove bolts (6). Remove refrigerant condenser (4).
Required Tools | |||
---|---|---|---|
Tool | Part Number | Part Description | Qty |
A | FT-2515 | Guide Bolt | 2 |
B | 138-7575 | Link Bracket | 2 |
- Position refrigerant condenser (4).
- Install bolts (6). Connect hose assemblies (5).
Show/hide table
Illustration 6 g01302315 - Install Tooling (B) and a suitable lifting device.
Show/hide table
Illustration 7 g01302312 - Install Tooling (A). Install grill (3). The weight of grill (3) is approximately
25 kg (55 lb) . - Install bolts (2).
Show/hide table
Illustration 8 g01302310 - Install bolts (1). Remove Tooling (A) and Tooling (B).
- Charge the air conditioner refrigerant into the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. . Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 5 | g01302317 |