TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Caterpillar


Output High IQAN XP2 A0-23

Usage:

TK711 101
Conditions Which Generate This Code:


Illustration 1g01297439

Connections for the swing clockwise solenoid

This diagnostic code is associated with the solenoid valve. The "Output High" code means that the module has determined that there is a short to ground in the solenoid circuit.

The possible causes of this diagnostic code are listed:

  • The energize circuit of the solenoid is shorted to ground.

  • The solenoid has failed.

  • The module has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of "Output High" for pin 23 of the IQAN XP2 A0 module is active before performing this procedure.

Note: Use a Digital Multimeter for the measurements in this procedure.

Test Step 1. CHECK THE SOLENOID.

  1. Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.

  1. Observe the status of the diagnostic code.

  1. Disconnect the solenoid with the active diagnostic code from the machine harness.

Expected Result:

"Output high" changes to "Output low" when the solenoid is disconnected.

Results:

  • YES - "Output high" changes to "Output low" when the solenoid is disconnected. The circuit is correct.

    Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.

    STOP

  • NO - "Output high" remains active. Proceed to Test Step 2.

Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. The solenoid remains disconnected from the machine harness.

  1. Disconnect the machine harness connector(s) from the module.

  1. At the machine harness connector, measure the resistance from the signal contact IQAN XP2 A0-23 (wire K932-WH) to all contacts that are used in the machine harness connectors for the module.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between IQAN XP2 A0-23 (wire K932-WH) and the circuit with the low resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.

  1. Inspect the harness connectors and clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors making sure that the connectors are fully seated and the clips for each connector are completely fastened.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Check the status of the "Output High" code for pin 23 of the IQAN XP2 A0 module.

Expected Result:

The "Output High" code for pin 23 of the IQAN XP2 A0 module is active.

Results:

  • YES - The "Output High" code for pin 23 of the IQAN XP2 A0 module is active. The diagnostic code has not been corrected.

    Repair: Check the solenoid circuit again.It is unlikely that the module has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the module.

    STOP

  • NO - The "Output High" code for pin 23 of the IQAN XP2 A0 module is not active. The diagnostic code does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Backup Alarm Always On
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-19
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Backup Alarm Always Off
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-17
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1406 - FMI 06
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1406 - FMI 05
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1406 - FMI 03
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1405 - FMI 06
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XT2 A0-17
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XT2 A0-19
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 1405 - FMI 05
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XT2 A0-2
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Transmission Control (Shift Lever)
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-25
770, 772, 773E, 773F, 777E and 777F Off-Highway Trucks and 775F Quarry Truck VIMS Truck Payload System CID 2183 - FMI 13
16M Motor Grader Battery Disconnect Switch
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-31
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Electrical Connector - Inspect
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-33
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-37
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A0-39
777E, 777F and 777G Off-Highway Truck Alternator - Remove and Install
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Output High IQAN XP2 A1-17
AccuGrade® - CD700 Grade Control System (GPS/ATS/Sonic/Cross Slope) General Maintenance Information
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.