816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Caterpillar


MID 081 - CID 0041 - FMI 03

Usage:

814F II BXG
Conditions Which Generate This Code:


Illustration 1g00888286

Schematic of the sensor power supply

This diagnostic code is associated with the power supply for the sensors. The FMI 03 means that the ECM has determined that the voltage of the sensor circuit is above normal.

The possible causes of the diagnostic code are listed:

  • The power circuit for the sensors is shorted to the +battery circuit.

  • The ECM has failed. This is unlikely.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0041 FMI 03 is active before performing this procedure.

Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.

System Response:

When this diagnostic code is active, the ECM will turn off the current to the sensors.

Test Step 1. CHECK FOR THE CORRECT VOLTAGE AT THE ECM

  1. Turn the key start switch to the ON position.

  1. Do not disconnect the harness connector from the ECM.

  1. At the back of the harness connector for the ECM, insert a 7X-1710 Multimeter Probe along the voltage supply wire (contact J2-12).

  1. Measure the voltage to frame ground.

Expected Result:

The voltage is 8.0 ± 0.5 DCV.

Results:

  • OK - The voltage is 8.0 ± 0.5 DCV. Proceed to Test Step 3.

  • NOT OK - The voltage is above 8.0 ± 0.5 DCV. Proceed to Test Step 2.

Test Step 2. CHECK THE POWER CIRCUIT OF THE SENSORS FOR A SHORT TO THE +BATTERY CIRCUIT.

  1. Turn the key start switch and the disconnect switch to the OFF position.

  1. Disconnect the machine harness connectors from the solenoid and the ECM.

  1. At the machine harness connector for the ECM, measure the resistance from contact J2-12 (wire 709-OR) to all contacts that are used in the machine harness connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.

  • NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-12 (709-OR) and the circuit that has a low resistance measurement.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.

  1. Inspect the contacts and clean the contacts of the harness connectors.

  1. Reconnect all harness connectors.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Operate the machine.

  1. Determine if the CID 0041 FMI 03 is active.

Expected Result:

The CID 0041 FMI 03 is active.

Results:

  • YES - The CID 0041 FMI 03 is active. The problem has not been corrected. The ECM may have failed.

    Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0041 FMI 03 is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A0-31
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A0-25
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A0-23
Emission Control System for Load Haul Dump Machines and Underground Articulated Trucks Emission Control System Troubleshooting
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Using Caterpillar Monitoring System to Determine Diagnostic Codes
D6K Track-Type Tractor Backup Alarm
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Diagnostic Code List
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Connector Locations
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer Service Tools
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer General Information
770, 772, 773E, 773F, 777E and 777F Off-Highway Trucks and 775F Quarry Truck VIMS Truck Payload System Diagnostic Code List
16M Motor Grader Additional Messages
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0041 - FMI 04
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A0-33
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0168 - FMI 00
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0168 - FMI 01
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0177 - FMI 03
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A0-37
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0177 - FMI 04
816F Series 2 Landfill Compactor, 815F Series 2 Soil Compactor and 814F Series 2 Wheel Dozer MID 081 - CID 0190 - FMI 02
Filtration Procedure for Large Wheel Loader and Landfill Compactor Hydraulic Oil {0680, 0768, 5050, 5056} Filtration Procedure for Large Wheel Loader and Landfill Compactor Hydraulic Oil {0680, 0768, 5050, 5056}
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A0-39
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XP2 A1-17
621G, 623G, 627G, 631G, 637G, and 657G Wheel Tractor-Scrapers Power Train Electronic Control System Service Tools
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.