Water Temperature Switches
Usage:
7W0872 Switch
Switch operates when the temperature increases to ... 101 to 103°C (214 to 217°F)
5L6435 Switch
Switch operates when the temperature increases to ... 98°C (209°F)
9Y0914 Switch
Socket terminal A is normally open below actuation temperature.
Pin terminal B is common.
Pin terminal C is normally closed below actuation temperature.
With a temperature increase to 100 to 103°C (212 ± 217°F), socket terminal A closes and pin terminal C opens.
With a temperature decrease to 95°C (202°F), socket terminal A opens and pin terminal C closes.
(1) Final torque for switch assembly ... 52 ± 8 N·m (38 ± 6 lb ft)
Caterpillar Information System:
3208 MARINE ENGINE ATTACHMENTS Sending Units For Water Temperature
3208 MARINE ENGINE ATTACHMENTS Indicators For Water Temperature
3208 MARINE ENGINE ATTACHMENTS Ammeters
3208 MARINE ENGINE ATTACHMENTS Sending Units For Oil Pressure
3208 MARINE ENGINE ATTACHMENTS Indicators For Transmission Oil Pressure
3208 MARINE ENGINE ATTACHMENTS Indicators For Gear Oil Pressure
3208 MARINE ENGINE ATTACHMENTS Indicators For Engine Oil Pressure
3208 MARINE ENGINE ATTACHMENTS Introduction
3208 MARINE ENGINE Testing & Adjusting
3208 MARINE ENGINE Systems Operation
3208 MARINE ENGINE Shutoff Solenoids
3208 MARINE ENGINE Electric Starter Motor
3208 MARINE ENGINE ATTACHMENTS Instrument Panel (Single & Dual Station Application)
3208 MARINE ENGINE ATTACHMENTS Junction Box
3208 MARINE ENGINE ATTACHMENTS Control Relay
3208 MARINE ENGINE ATTACHMENTS Magnetic Starting Switch Assembly
3208 MARINE ENGINE ATTACHMENTS Circuit Breakers
3208 MARINE ENGINE ATTACHMENTS Tachometer Calibration Chart
3208 MARINE ENGINE ATTACHMENTS Digital Tachometer
3208 MARINE ENGINE ATTACHMENTS Service Meters
3208 MARINE ENGINE ATTACHMENTS Magnetic Pickup
3208 MARINE ENGINE ATTACHMENTS Pressure Switches
3208 MARINE ENGINE ATTACHMENTS Temperature Sensors
3208 MARINE ENGINE ATTACHMENTS Cooling System Pressure Cap