CONFIDENTIAL TIBU3888-00

TECHNICAL INFORMATION BULLETIN

June 25, 2003

Marine Engines

3196 (2XR)

3406E (9WR)

3412E (9KS, 9PW)

3126B (3GS, 9ZF)

3126 (1ZJ, 6MK)

C-18 (CKH)

C-30 (CLX)

C-9 (CSN)

C-12 (9HP)

 

Component Code: 1408

SUBJECT: Certain 225-6118 Harness Cables Used with the Plug and Run Wiring System (Caterpillar Data Link) May Need to be Rewired

PROBLEM:

Caterpillar Data Link leads are located in the 8T-8736 Receptacle on the 225-6118 Harness Assembly. If the change level of the 225-6118 Harness Assembly is prior to 02 (225-6118-02), the location of the Data Link leads in the 8T-8736 Receptacle may be incorrect.

SOLUTION:

Illustration 1. Location of the part number label.

Refer to the part number label. This label will be located approximately 150 mm (6 inches) from the connector (see Illustration 1). If the label indicates 225-6118-02 or higher, no action is required. If the label does not indicate a change number (225-6118), perform the following steps.

Illustration 2. 225-6118 Receptacle wiring.

 

  1. Remove the 18 AWG green wire (CAT Data Link ? Negative) from position "D" in receptacle 8T-8736.
  2. Remove the 18 AWG orange wire (CAT Data Link ? Positive) from position "E" in receptacle 8T-8736.
  3. Install the green wire (CAT Data Link ? Negative) in position "E" in receptacle 8T-8736.
  4. Install the orange wire (CAT Data Link ? Positive) in position "D" in receptacle 8T-8736.

 

When the receptacle is wired correctly, it will conform to the following table.

225-6118 Receptacle Wiring

Color ? AWG

Function

Position

Red ? 18

Key-switch Remote Run

A

Black ? 18

Battery ? Negative

B

Orange ? 18

CDL ? Positive

D

Green ? 18

CDL ? Negative

E

 

COPYRIGHT 2003 CATERPILLAR
ALL RIGHTS RESERVED

Caterpillar Information System:

Certain 225-6118 Harnesses (Caterpillar Data Link) Used with the Plug and Run Wiring System May Contain Shielding Certain 225-6118 Harnesses (Caterpillar Data Link) Used with the Plug and Run Wiring System May Contain Shielding
All Series 300 Uninterruptible Power Supply (UPS) Systems that have either a 180-6221 Static Switch Interface, 201-2606 Bypass Cabinet Controller or a 229-8307 Board Assembly (ZigZag Controller) All Series 300 Uninterruptible Power Supply (UPS) Systems that have either a 180-6221 Static Switch Interface, 201-2606 Bypass Cabinet Controller or a 229-8307 Board Assembly (ZigZag Controller)
New Engine Software Removed from SIS Web New Engine Software Removed from SIS Web
Possible Cam Gear Bolt Failures Possible Cam Gear Bolt Failures
Shock Hazard for the VR-6 and K65-12B Voltage Regulators Shock Hazard for the VR-6 and K65-12B Voltage Regulators
Certain 3E-5239 Relay Assemblies May Fail Certain 3E-5239 Relay Assemblies May Fail
Check Bolt Torque on Flex Plates of Certain 3508B Single Bearing Generator Sets Check Bolt Torque on Flex Plates of Certain 3508B Single Bearing Generator Sets
Poor Mid-Range Acceleration and Smoke in 3176 and 3196 Marine Engines Poor Mid-Range Acceleration and Smoke in 3176 and 3196 Marine Engines
Inaccurate Oil Pressure Indication on C-12 Marine Engines with Left Hand Service Inaccurate Oil Pressure Indication on C-12 Marine Engines with Left Hand Service
Overburdened Power Transformers Can Lead to Power Transformer Failures Overburdened Power Transformers Can Lead to Power Transformer Failures
Loose Connections on Voltage Regulators Can Lead to Above Normal Voltage Output and Regulator Failure Loose Connections on Voltage Regulators Can Lead to Above Normal Voltage Output and Regulator Failure
Cracking of PMG Capacitor Cases Due to Prolonged Elevated Temperatures in Certain High Voltage Generators (Kato). Cracking of PMG Capacitor Cases Due to Prolonged Elevated Temperatures in Certain High Voltage Generators (Kato).
EMCPII+ Wall-Mounted Panel Schematics EMCPII+ Wall-Mounted Panel Schematics
The Clutch In The Compressor May Fail If The Refrigerant Charge Exceeds Specifications The Clutch In The Compressor May Fail If The Refrigerant Charge Exceeds Specifications
Water Pump Cover Failures Water Pump Cover Failures
Low Hour Turbocharger Failures Low Hour Turbocharger Failures
Liner Flange Breakage Liner Flange Breakage
Caterpillar Electronic Technician (ET) Support of Transmission Temperature and Transmission Pressure Set Points Caterpillar Electronic Technician (ET) Support of Transmission Temperature and Transmission Pressure Set Points
Exhaust Leak on XQ Rental Generator Enclosure Packages Exhaust Leak on XQ Rental Generator Enclosure Packages
Idle Instability Idle Instability
Adapter Welds And Base Edge Cracking Adapter Welds And Base Edge Cracking
Improper Wiring for �Remote Sense� on Marine Engine Insulated Ground Alternators Improper Wiring for �Remote Sense� on Marine Engine Insulated Ground Alternators
Engine will not start Engine will not start
Certain 225-6120 Harness Cables Used with the Plug Run Wiring System (Caterpillar Data Link) May Need to be Rewired Certain 225-6120 Harness Cables Used with the Plug Run Wiring System (Caterpillar Data Link) May Need to be Rewired
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.