Usage:
480 (2BZ) LEXION COMBINES
Problem:
Thirty LEXION 460 and twelve LEXION 480 Combines were shipped from the factory without verification of the ground speed calibration factor setting.
Solution:
Check the "impulses/100m" setting on LEXION 460 (9FW521), (9FW523-531), (9FW533-534), (9FW536-552), (9FW554); LEXION 480 (2BZ493-495), (2BZ497), (2BZ500-501), (2BZ503), (2BZ506), (2BZ508-509), (2BZ510), (2BZ512) Combines. Verify that setting is correct for the tires that exist on the machine. The following references provide the procedures for checking ground speed settings and adjusting the settings.
For machines equipped with CEBIS, refer to Operation and Maintenance Manual, "Tachometer Adjustment - CEBIS".
For machines equipped with IMO, refer to Operation and Maintenance Manual, "Tachometer Adjustment - IMO".
COPYRIGHT 1999 CATERPILLAR ALL RIGHTS RESERVED