Usage:
27Feb2015 |
Before/After | PRODUCT SUPPORT PROGRAM FOR REPLACING THE FUSES ON CERTAIN PMG3516C (XQ1475G) POWER MODULES |
|
1417 | PS44656 |
NOTE: | Caterpillar’s obligations under this Service Letter are subject to, and shall not apply in contravention of, the laws, rules, regulations, directives, ordinances, orders, or statutes of the United States, or of any other applicable jurisdiction, without recourse or liability with respect to Caterpillar. |
NOTE: | This Program must be administered either before or after failure. In either case the decision whether to apply the Program is made by the dealer. When reporting the repair, use "PS44656" as the Part Number and "7755" as the Group Number. If administered before failure, use "56" as the Warranty Claim Description Code and "T" as the SIMS Description code. If administered after failure, use "96" as the Warranty Claim Description Code, and "Z" as the SIMS Description Code. |
NOTE: | The information supplied in this service letter may not be valid after the termination date of this program. Do not perform the work outlined in this Service Letter after the termination date without first contacting your Caterpillar product analyst. |
TERMINATION DATE |
28Feb2017 |
PROBLEM
The existing .5 amp fuses can fail on certain PMG3516C (XQ1475G) Power Modules with an utility multifunctional relay option. |
AFFECTED PRODUCT
Model | Identification Number |
PMG3516C | JKK00127, 130, 132, 136, 143, 148-149, 157, 161, 192, 197, 199, 201, 203, 205, 209, 216-217, 231 |
PARTS NEEDED
Qty |
Part Number | Description |
9 | 1259948 | FUSE-MIDGET |
In order to allow equitable parts availability to all participating dealers, please limit your initial parts order to not exceed 32% of dealership population. This is an initial order recommendation only, and the ultimate responsibility for ordering the total number of parts needed to satisfy the program lies with the dealer. |
ACTION REQUIRED
WARNING: Injury can occur to personnel if the rework is done improperly. Personal Protective Equipment (PPE) suitable to the work being performed must be worn when performing the rework. WARNING: The power module must be isolated electrically before and while the rework is performed. Follow the proper lockout tag out procedures to protect against the unexpected energization or start up of the power module. Failure to follow these warnings could result in injury to personnel during service. This program only applies to XQ1475G Power Modules with the UMR option pictured in Image 1. Verify that the Power Module has an UMR installed before ordering replacement 1.5 amp fuses. Instructions 1. Remove lower generator control panel cover. 2. Remove the 9 fuses as shown in Image 1 3. Install 9 125-9948 fuses 4. Install lower generator control panel cover. Installation is complete. |
Image1 |
SERVICE CLAIM ALLOWANCES
0-24 mo |
NOTE: This is a 1.0-hour job | ||||||
PARTS DISPOSITION
Handle the parts in accordance with your Warranty Bulletin on warranty parts handling. |