Usage:
Start By:
a. remove radiator, oil cooler and condenser
Fluid Spillage Containment
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "Tools And Shop Products Guide", NENG2500 for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
1. Remove four bolts (1). Remove bolt (2) and bolt (4). Remove two spacers (3) and remove condenser (5).
2. Remove four bolts (6). Remove oil cooler (7) from radiator (8).
End By:
a. install radiator, oil cooler and condenser