D348 INDUSTRIAL & MARINE ENGINES Caterpillar


Pressure Switches

Usage:

Rating when used with alarm or switch:

240 Volts AC ... 15 A

120 Volts AC ... 15 A

32 Volts DC ... 4 A

24 Volts DC ... 6 A

12 Volts DC ... 8 A

6 Volts DC ... 15 A

5L5500 Fuel Pressure Switch

With an increase in pressure, switch closes at ... 12 psi(85 kPa)

With a decrease in pressure, switch opens at ... 10 psi(70 kPa)

3L6306 Oil Pressure Switch

With a decrease in pressure, switch closes at ... 6 to 10 psi(40 to 70 kPa)

2L3402 Oil Pressure Switch

With an increase in pressure, switch closes at ... 3 to 4 psi(20 to 25 kPa)

1N5833 Oil Pressure Switch

With an increase in pressure, switch opens at ... 5 to 7 psi(35 to 50 kPa)