Service Meter And Tachometer Drive
Usage:
TYPICAL ILLUSTRATION
Torque for thrust screw ... 50 ± 3 lb.ft.(70 ± 4 N·m)
(1) Torque for bolts (that hold service meter on the drive) ... 96 ± 24 lb.in.(11 ± 3 N·m)
(2) 4L8395 Shim, thickness ... .003 in.(0.08 mm)
Use shims (2) needed to get end clearance (3).
(3) Shaft end clearance ... .001 to .008 in.(0.03 to 0.20 mm)
Caterpillar Information System:
D348 INDUSTRIAL & MARINE ENGINES Electric Tachometer
D348 INDUSTRIAL & MARINE ENGINES Mechanical Tachometers
D348 INDUSTRIAL & MARINE ENGINES Mechanical Gauges (Color Code Dial Face)
D348 INDUSTRIAL & MARINE ENGINES 5L7441 Resistor (For Use With 32 V Systems)
D348 INDUSTRIAL & MARINE ENGINES Electric Gauges
D348 INDUSTRIAL & MARINE ENGINES Sending Unit For Engine Oil Pressure (12 V - 24 V - 32 V)
D348 INDUSTRIAL & MARINE ENGINES Sending Units For Water Temperature
D348 INDUSTRIAL & MARINE ENGINES Pressure Switches
D348 INDUSTRIAL & MARINE ENGINES Water Temperature Contactor
D348 INDUSTRIAL & MARINE ENGINES Shut-Off Solenoids
D348 INDUSTRIAL & MARINE ENGINES Starter Magnetic Switches
D348 INDUSTRIAL & MARINE ENGINES Starter Solenoids
D348 INDUSTRIAL & MARINE ENGINES Electric Service Meter
D348 INDUSTRIAL & MARINE ENGINES Air Starting Motors
D348 INDUSTRIAL & MARINE ENGINES Pressure Regulating Valve For Air Starting Motor
D348 INDUSTRIAL & MARINE ENGINES Hydraulic Starting Motor
D348 INDUSTRIAL & MARINE ENGINES Charging Pump For Hydraulic Starter
D348 INDUSTRIAL & MARINE ENGINES Hand Pump For Hydraulic Starter
D348 INDUSTRIAL & MARINE ENGINES Pressure Accumulator For Hydraulic Starter
D348 INDUSTRIAL & MARINE ENGINES V-Belt Tension Chart
D348 INDUSTRIAL & MARINE ENGINES Systems Operation
D348 INDUSTRIAL & MARINE ENGINES Testing And Adjusting
D348 INDUSTRIAL & MARINE ENGINES Air Starting Motors
D348 INDUSTRIAL & MARINE ENGINES Hydraulic Starting System