1986/02/03 Caterpillar


High Silicates In Antifreeze{1350}

Usage:


SUPPLEMENT: 05/26/86

SERVICE MAGAZINE, FEBRUARY 3, 1986, PAGE 9, "High Silicates In Antifreeze". Under the section, "Use lesser amounts of antifreeze", Caterpillar recommends a minimum 30% ethylene glycol mixture with water for 3306B, and 3406B Engines with ATAAC to prevent water pump cavitation.

--------------- END SUPPLEMENT ---------------

There has been an increasing number of reported field problems related to inhibitor dropout from high silicate commercial antifreeze which involve radiator and cooling system plugging, increased deposits resulting in overheating and water pump seal leakage. Commercial antifreeze formulations in the United States have changed to accommodate the corrosion requirements of aluminum engine components used in automotive gasoline engines. This change involved increasing the concentration of silicates, an effective means to protect aluminum parts. When these antifreezes are mixed with water, especially hard water, and then added with supplemental corrosion inhibitors, several situations can and do occur:

... The total solids in the coolant solution increase to cause an insoluble condition for unstable chemicals, such as silicates and phosphates. These solids can build up in latent areas and cause plugging or loss of heat transfer.

... A silica gel (polymerization of the silicate) can be formed. These gel formations can result in loss of cooling or heating in radiators, aftercoolers and cab heater cores by coating or plugging tubes. It usually deposits in the cooler section of the cooling system, such as radiator bottom tank, etc.

... A large quantity of precipitants combined with the gel in the cooling system can cause wear leading to water pump seal failures.

Some steps can be taken to minimize the occurrence of silicate dropouts.

* Use antifreeze containing low silicates.

Most commercially available antifreezes are formulated for gasoline engine applications and, therefore, will have high silicate content. A specification that limits the amount of silicate content is the GM-6038.

This product is not readily available at this time, but many antifreeze manufacturers are making it available because of customer requests. Use of antifreeze meeting GM-6038 may not necessarily prevent the problem but will certainly reduce the severity.

* Use good quality water.

The tendency of silicates to precipitate out of solution increases with increasing water hardness. Hard water, or water with high levels of calcium and magnesium ions, encourages the formation of the gel especially after a number of heating and cooling cycles.

Caterpillar prefers the use of distilled water or deionized water to reduce the potential and the severity of silicate dropouts. The minimum acceptable water that should be used in a coolant mixture of 50% antifreeze and 50% water must have the characteristics shown in Chart A from "Know Your Cooling System", SEBD0518-02. Using water that meets this requirement may not prevent silicate dropout totally but should minimize the rate to acceptable levels.

* Use lesser amounts of antifreeze.

The reason for the use of antifreeze or ethylene glycol is strictly for freeze protection. In many areas of the world where freeze protection is not needed (in the tropics), the use of plain water treated with a coolant conditioner inhibitor package is sufficient to protect the engine against corrosion and pitting. Therefore, in those areas where there is no need for protection down to -37°C (-34°F) use of a 50% antifreeze is not essential. Chart B provides some guidelines for the amount of antifreeze and freeze protection temperatures.

Caterpillar Information System:

1986/02/03 Time Delay (Relay) Switches Should Be Tested Before They Are Returned For Warranty Claims{7426}
1986/02/03 New Oil Viscosity Recommendations For All 7200 Series Marine Transmissions{3351}
1986/02/03 Extend Exciter Stator Life In Humid, Salty Environments{4453,4454,4450}
1986/02/03 5N563 Self-Excited SR4 Generators Use Different Type Regulator And A Power Autotransformer{4450}
1986/01/27 Check 5P9729 Track Repair Group For Correct Nuts{0729,0700}
1986/01/27 New Service Tools Available{0600}
1986/01/27 Uprated 3500 Series Engines Use Stronger Pistons, New Connecting Rods And New Piston Pins{1214,1218,1225}
1986/01/27 Stronger Cylinder Heads Used{1100}
1986/01/27 Uprated 3500 Series Engines Now Available{1000}
1986/01/20 Oil Total Base Number (TBN) Test Kit Available{1300}
1986/01/20 Padlock Covers Keep Out Debris{7315,7300}
1986/01/13 Checking Or Adjusting Valve Clearances{1105,1208,1123}
1986/02/03 Special Instructions Packaged With Turbocharger Cartridge Repair Kits May Be Incorrect{1053}
1986/02/03 Service Tools Now Available For Charging Fire Suppression Systems{0647,7401}
1986/02/10 New Cylinder Liner Available{1201}
1986/02/10 Blue Lens Available For Beacon Lamp{7328,7309}
1986/02/17 New Service Parts Available To Repair Scraper Components{6201,6203,6204,6207,6212}
1986/02/17 New 8T2998 Lubricant Available{0645,1210}
1986/02/17 New Fuel Injector Available To Reduce Smoke At Low RPM and Loads{1050,1254}
1986/02/17 New Clip Added To Water Lines Group{1380,1350}
1986/02/24 New Track Link Assembly And Sprocket Segments Used {4171,4155}
1986/02/24 Air-To-Air Aftercooler Test Group Available {0768,1063,0600}
1986/02/24 Longer Bolts Used In Turbocharger Air Lines Groups {1052}
1986/02/24 Truck Engine Performance Checklist Available For North American Dealers {0337,0372}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.