Usage:
Start By:
a. Install the steering frame lock pin. Refer to Disassembly and Assembly, "Steering Frame Lock Pin - Remove and Install" for the machine that is being serviced.
b. Release the pressure from the hydraulic system. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release" for the machine that is being serviced.
c. Remove the torque converter scavenge pump. Refer to Disassembly and Assembly, Power Train, "Torque Converter Scavenge Pump - Remove" for the machine that is beint serviced.
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide", for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose of fluids according to local regulations and mandates. |
NOTE: Put identification marks on all lines, on all hoses, on all wires and on all tubes for installation purposes. Plug all lines, all hoses and all tubes. This will help prevent fluid loss and this will help to prevent contaminants from entering the system.
1. Drain the oil from the hydraulic tank into a suitable container for storage or disposal. The hydraulic tank capacity is 125 liters (33 US gal).
2. Disconnect hose assemblies (1) and (2) from implement pump (3).
3. Disconnect tube assembly (4) from the implement pump.
4. Loosen three bolts (7) and the washers that hold bracket (5) to the engine.
5. Remove four bolts (6), the washers and the two spacers that hold manifold and hose assembly (8) to the implement pump. Move manifold and hose assembly (8) away from the implement pump.
6. Install Tooling (A) on the implement pump, as shown. Attach a hoist and a suitable lifting chain to Tooling (A). Remove two bolts (9) and the washers that hold implement pump (3) to the torque converter housing. Remove the implement pump. The weight of the implement pump is 54 kg (119 lb).
7. Remove O-ring seal (10) from the implement pump.