Switches
Usage:
Fuel Pressure
107-0612
Actuation pressure ... 93 ± 21 kPa (14 ± 3 psi)
Deactuation pressure ... 70 ± 21 kPa (10 ± 3 psi)
Contact position ... normally open below deactuation pressure
(1) Final installation tighten to a torque of ... 30 ± 5 N·m (22 ± 4 lb ft)
3T4418
Actuation pressure ... 93 ± 21 kPa (14 ± 3 psi)
Deactuation pressure ... 70 ± 21 kPa (10 ± 3 psi)
Contact position normally open below ... 48 kPa (7 psi)
(1) Final installation tighten to a torque of ... 22.5 ± 2.5 N·m (17 ± 2 lb ft)
Pressure
With an increase in pressure, switch opens at ... 93 ± 20 kPa (14 ± 3 psi)
With an decrease in pressure, switch closes at ... 69 ± 20 kPa (10 ± 3 psi)
Caterpillar Information System:
3408C & 3412C INDUSTRIAL ENGINES Sensors
3408C & 3412C INDUSTRIAL ENGINES Indicators
3408C & 3412C INDUSTRIAL ENGINES Service Meter
3408C & 3412C INDUSTRIAL ENGINES Magnetic Pickup
3408C & 3412C INDUSTRIAL ENGINES Electric Starting Motor
3408C & 3412C INDUSTRIAL ENGINES Alternators And Regulators
3408C & 3412C INDUSTRIAL ENGINES Alternator Mounting Group
3408C & 3412C INDUSTRIAL ENGINES Rear Drive Gear
3408C & 3412C INDUSTRIAL ENGINES Vibration Damper
3408C & 3412C INDUSTRIAL ENGINES Flywheel
3408C & 3412C INDUSTRIAL ENGINES Flywheel Adapter
3408C & 3412C INDUSTRIAL ENGINES Flywheel Housing
3408C & 3412C INDUSTRIAL ENGINES Circuit Breakers
3408C & 3412C INDUSTRIAL ENGINES Shutoff Solenoid
3408C & 3412C INDUSTRIAL ENGINES Systems Operation
3408C & 3412C INDUSTRIAL ENGINES Testing & Adjusting
C-10, C-12 & 3406E TRUCK ENGINE Schematic
G3400 & G3500 GAS ENGINE DRIVEN CHILLER ENGINE CONTROL PANEL Information Section
G3400 & G3500 GAS ENGINE DRIVEN CHILLER ENGINE CONTROL PANEL Operation Section
UG ACTUATOR General Information
UG ACTUATOR Installation
UG ACTUATOR Operation & Maintenance
UG ACTUATOR UG Actuator Operation
UG ACTUATOR Specifications