- Electric Power Generation
- C27 PET GEN SET (S/N: EGG1-UP)
- Generator Set
- C27 GEN SET (S/N: N1B1-UP; T4Z1-UP)
- C32 (S/N: BT41-UP; WJD1-UP)
- Industrial Engine
- C27 (S/N: AT41-UP)
- C27 INDUSTRIAL (S/N: JFJ1-UP; RAM1-UP)
- C32 INDUSTRIAL (S/N: NST1-UP)
- C27 INDUSTRIAL (S/N: JFJ1-UP; RAM1-UP)
- Locomotive Engine
- C27 LOCO (S/N: WJC1-UP)
- Off-Highway Truck/Tractor
- 777G (S/N: T5A1-UP; RDR1-UP)
- Petroleum Engine
- C27 PETROLEUM (S/N: NAR1-UP)
- C32 PETROLEUM (S/N: SDK1-UP)
- Quarry Truck
- 773G (S/N: JWS1-UP; T5T1-UP)
- 775G (S/N: T5F1-UP; MJS1-UP)
- Track-Type Tractor
- D10T2 (S/N: JJW1-UP)
- D11T (S/N: JEL1-UP; JNS1-UP)
- Wheel Dozer
- 844K (S/N: MBE1-UP; M4R1-UP; K4Y1-UP)
- 854K (S/N: KK31-UP; KK61-UP; H8M1-UP)
- Wheel Loader
- 990K (S/N: A9P1-UP; M9P1-UP; K9X1-UP)
- 992K (S/N: 8801-UP; KK21-UP; KK41-UP)
- 993K (S/N: Z4D1-UP; Z8D1-UP; Z8Z1-UP)
- 992K (S/N: 8801-UP; KK21-UP; KK41-UP)
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.
Problem
C27 and C32 Tier 4 interim and Tier 4 final NOx Reduction System (NRS) coolers may have contingent damage when there is another cooling system failure.
Solution
Depending on the temperatures reached on the NRS cooler during the failure, additional inspection and/or replacement of the opposing cooler will be required. A low temperature failure of one cooler will require inspection of the opposing cooler and validation of the cooler per the reuse and salvage guidelines. A high temperature failure or repeat failure on one side of the engine will require both coolers being replaced.