Note: It is not possible to configure the "bypass times" for an individual electronic key. The "bypass times" are not associated to an individual electronic key.
"Security System Bypass Times" are time periods that can be set to disarm the Machine Security System automatically. An electronic key is not required during these periods. This feature can be used for the normal work shift of the machine. Outside the normal work shift, the Machine Security System would be armed. When the MSS is armed, an electronic key is required to start the machine. This feature would minimize the number of electronic keys that are needed.
"Sunday Security System Bypass Start Time" | 00:00 |
"Sunday Security System Bypass Stop Time" | 00:00 |
"Monday Security System Bypass Start Time" | 6:00 |
"Monday Security System Bypass Stop Time" | 18:00 |
"Tuesday Security System Bypass Start Time" | 6:00 |
"Tuesday Security System Bypass Stop Time" | 18:00 |
"Wednesday Security System Bypass Start Time" | 6:00 |
"Wednesday Security System Bypass Stop Time" | 18:00 |
"Thursday Security System Bypass Start Time" | 6:00 |
"Thursday Security System Bypass Stop Time" | 18:00 |
"Friday Security System Bypass Start Time" | 6:00 |
"Friday Security System Bypass Stop Time" | 12:00 |
"Saturday Security System Bypass Start Time" | 12:00 |
"Saturday Security System Bypass Stop Time" | 12:00 |
Table 1 shows an example of "Security System Bypass". The "Start Time" is the time when the Machine Security System will disarm. The Machine Security System will return to the "armed" state at the "Stop Time". Between these two periods of time, any Caterpillar key will operate the machine. Thus, the MSS is disarmed during this time period.
All times are based on a 24 hour clock. For example, 6:00 am is 06:00 and 3:00 pm is 15:00. The Machine Security System will be disarmed during the times that are listed below: Monday through Thursday from 06:00 to 18:00
On Friday, the MSS is disarmed for only half of the workday. After 12:00 on Friday, the Machine Security System will be armed automatically. Operation will be restricted to operators with electronic keys that are authorized in the MSS3s ECM on that machine. Refer to Table 1.
The Machine Security System is "armed" on the weekend. Because the "Start Time" and the "Stop Time" are set for the same time, the Machine Security System will be armed throughout the day.