Machine Security System (MSS3i) Integrated Caterpillar


Configuration

Usage:

725C2 2L6

"Fleet/Key Configuration"

The "Fleet/Key Configuration" function allows you to configure and manage a Machine Security System (MSS) enabled machine or a set of machines. The function allows you to program, load, and save a set of configuration parameters and key information. The information can be loaded from or programmed to the MSS. This information can also be saved to or loaded from a file.

Once a file is saved in"Fleet/Key Configuration", File Management can be used to export the file as a *.MSS file. The exported *.MSS file can then be imported into the MSS Key Management Software program, for management of the "Fleet/Key" information.

Loading Data from the ECM

  1. Connect the service tool to the Machine Security System ECM that you want to copy.

  2. Select "Copy Configuration" from the "Service" menu, and then select "Fleet/Key Configuration" from the submenu.

    Note: Changing the "Fleet/Key Configuration" requires a key with master access level or a factory password.

  3. If there is no recently loaded data available, the "No data is available..." message box will display.

  4. Press "Yes" to load data from the ECM. The "ECM Selector" dialog box displays.

    Press "No" if you do not want to load data. The "Fleet/Key Configuration blank screen" displays.

    Note: Pressing the "Load from ECM" push button from the "Fleet/Key Configuration" screen also displays the "ECM Selector" dialog box.

  5. Highlight the Machine Security System ECM you wish to copy from and then press "OK". As the data is loading from the ECM, the "Please wait" message displays. Then, the "Loading data from ECM" progress bar displays.

  6. Press "Cancel" to exit the "ECM Selector" dialog box. Press "Help" to open online help for assistance.

    You can cancel the loading process at any time, by pressing the "Cancel" push button. The "Are you sure..." message box displays. Press "Yes" to cancel loading the data or press "No" not to cancel loading the data.

  7. When the data has been successfully loaded, "The data has been successfully loaded" message box displays.

  8. Press "OK". The "Fleet/Key Configuration" screen displays with the "Program ECM" and the "Save to File" push buttons are enabled.

    Note: The data must be saved to a file before you disconnect from the service tool or the data is lost.

Saving the Configuration to a File

  1. Press the "Save to File" push button. The "Print New Document to File" dialog box displays.

    Note: If you do not have a file open, the "Printing" dialog box asks you to open a file, create a new file, or cancel. Choose the appropriate button to continue.



    Illustration 1g03864372
    Saving Configuration to a File

  2. Enter a document name and description in the appropriate text boxes. Press the "OK"button. The "Fleet/Key Configuration saved successfully" message box displays. Press the "Cancel" push button to exit the "Print New Document To File" dialog box without saving the file. You will return to the "Fleet Configuration" dialog box.

  3. Press "OK" to return to the "Fleet/Key Configuration" screen.

Loading Data from a File

  1. Connect the service tool to the ECM to be programmed.

  2. Select "Copy Configuration" from the "Service" menu, and then select "Fleet/Key Configuration" from the submenu.

    If there is no recently loaded data available, the "No data is available..." message box displays.

  3. Press "No" that you do not want to load data from the ECM. The "Fleet/Key Configuration screen" displays.

  4. Press the "Load from File" push button. The "File Management" dialog box displays.

  5. If the "Load from File" push button is pressed with unsaved data on the "Fleet/Key Configuration" screen, a message box displays asking if you want to save changes.

  6. From the" File Management" dialog box, highlight the file from the "Files" list box. Next highlight the "Fleet/Key Configuration document" that you want to load from the "Documents" list box.

  7. Open the document. As the data loads, a progress bar displays. Then, the "Fleet Configuration" message box displays.

  8. Press "OK". The "Fleet/Key Configuration" screen displays with the file data.

Programming the ECM

Note: The data must be loaded from a file before you can program an ECM.

Note: Keys that are already programmed into the ECM can be unchecked from the "Fleet/Key Configuration" screen. This unchecking method is only a time saving measure. If you do not uncheck the keys, the "Program ECM" message box displays. This message box lists all keys that were not programmed because the keys were already stored.

Press the "Program ECM" push button. The "ECM Selector" dialog box displays.



Illustration 2g03860018
ECM Selector dialog box

Highlight an ECM and press "OK" The "Please wait" message box displays. Then the "Testing ECM" progress bar displays.

You can cancel the uploading process at any time, by pressing the "Cancel" push button. The "Are you sure..." message box displays. Press "Yes" to cancel uploading the data or "No" not to cancel.

Refer to the following procedures when you "Append" or "Replace" the key list. Refer to the "Append" section to append the list. Refer to the "Replace" section to replace the list.

Append

  1. Connect the service tool to the ECM to be programmed.

  2. Start the Caterpillar Electronic Technician (ET)

    Note: This procedure requires Caterpillar Electronic Technician (ET) version 2002A or later.



    Illustration 3g03864388
    Copy Configuration, Service Menu, Fleet/Key Configuration

  3. Select "Copy Configuration" from the "Service" menu, and then select "Fleet/Key Configuration" from the submenu.

  4. Open the document. As the data loads, a progress bar displays. Then, the "Fleet Configuration" message box displays.

  5. Press "OK". The "Fleet/Key Configuration" screen displays with the file data.

  6. Click on the "Program ECM" button. This button displays the Fleet key information box.


    Illustration 4g03864392
    Append

  7. Click on the "Append" button.


    Illustration 5g00900409

  8. Click on the "Yes" button if you are prompted.

When the data has been successfully uploaded, the "Programming complete." message box displays. Press "OK"

Note: MSS can store a maximum number of 50 keys at one time. "Fleet/Key Configuration" determines the number of keys slots not programmed on the MSS. You cannot program more keys than the maximum number allowed. A message box displays informing you of the number of key slots available or that there are no more key slots are available. Remove enough keys in order to add new key information.

STOP.

Replace

  1. Connect the service tool to the ECM to be programmed.

    Note: This procedure requires Caterpillar Electronic Technician (ET) version 2015A or later.

  2. Start the Caterpillar Electronic Technician (ET)


    Illustration 6g03864422
    Copy Configuration, Service Menu

  3. Select "Copy Configuration" from the "Service" menu, and then select "Fleet/Key Configuration" from the submenu.

  4. From the" File Management" dialog box, highlight the file from the "Files" list box. Next highlight the "Fleet/Key Configuration document" that you want to load from the "Documents" list box.

  5. Open the document. As the data loads, a progress bar displays. Then, the "Fleet Configuration" message box displays.

  6. Press "OK". The "Fleet/Key Configuration" screen displays with the file data.

  7. Click on the "Program ECM" button. The Fleet


    Illustration 7g03864431
    Replace

  8. Click on the "Replace" button.


    Illustration 8g00900409

  9. Click on the "No" button if you are prompted.

When the data has been successfully uploaded, the "Programming complete." message box displays. Press "OK"

Note: MSS can store a maximum number of 50 keys at one time. "Fleet/Key Configuration" determines the number of keys slots not programmed on the MSS. You cannot program more keys than the maximum number allowed. A message box displays informing you of the number of key slots available or that there are no more key slots are available. Remove enough keys in order to add new key information.

STOP.

Caterpillar Information System:

Machine Security System (MSS3i) Integrated Factory Password - Obtain
Machine Security System (MSS3i) Integrated Time - Set
Machine Security System (MSS3i) Integrated Scheduled Access - Program - Security System Bypass
120 and 120 AWD Motor Grader Stopping the Engine if an Electrical Malfunction Occurs
Machine Security System (MSS3i) Integrated Key - Program
Machine Security System (MSS3i) Integrated Troubleshooting
Machine Security System (MSS3i) Integrated General Information
Machine Security System (MSS3i) Integrated Data Link
Machine Security System (MSS3i) Integrated System Components
Procedure to Use the Correct Mounting Bolts with the 10R-2356 Flywheel As {1156} Procedure to Use the Correct Mounting Bolts with the 10R-2356 Flywheel As {1156}
Machine Security System (MSS3i) Integrated Electronic Control Module (ECM)
Machine Security System (MSS3i) Integrated Service Operation Using Service Tool
Machine Security System (MSS3i) Integrated Machine Security System - Uninstall
Machine Security System (MSS3i) Integrated Glossary of Terms
Machine Security System (MSS3i) Integrated System Schematic
G3600 A4 Engines Engine Air Cleaner Service Indicator - Inspect
120 and 120 AWD Motor Grader Lifting and Tying Down the Machine
3412 Generator Set Engine Stalls Immediately After Starting
2015/06/18 Cat Reman Announces Availability of New Wheels With Installed Studs for Certain Machines {4201}
120 and 120 AWD Motor Grader Jacking Locations
Autonomy Log Processing Setup {7008, 7605} Autonomy Log Processing Setup {7008, 7605}
120 and 120 AWD Motor Grader Engine Starting with Auxiliary Start Receptacle
120 and 120 AWD Motor Grader Tire Shipping Pressure
120 and 120 AWD Motor Grader Access Doors and Covers
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.