Some of the components that are connected to the electronic control modules can be calibrated by using the Caterpillar Electronic Technician (Cat ET).
Calibrations are performed when directed by troubleshooting procedures or replacing a component within the calibrated system.
The calibration of a component allows the ECM to determine the correct output level. The calibration also allows the ECM to determine the correct input signal of displacement.
For more information on error codes that may occur during calibration refer to Testing and Adjusting, UENR2381, "Calibration Error Codes".
Illustration 1 | g03623456 |
Required Tools | ||||
---|---|---|---|---|
Tool | Item | Qty | Part
Number |
Description |
C | 1 | 317-7484(1) | Communication Adapter Gp | |
C1 | 1 | 370-4617 | Cable As (USB PC Communication) | |
C2 | 1 | 317-7485 | Communication Adapter III | |
C3 | 1 | 327-8981 | Cable As (Data Link) | |
C4 | 1 | 317-7492 | Cable As Wireless Radio | |
C5 | 1 | JERD2129 | Caterpillar Electronic Technician (Cat ET) |
(1) | Cat Electronic Technician (ET) and Software CD, NETG5057 are required when using the communication adapter. |
725C 725C2 Cat ET Calibrations
Illustration 2 | g06048380 |
Calibration screen |
Transmission/Chassis ECM Calibrations
The following calibrations can be performed to the Transmission/Chassis ECM:
- Retarder Performance Calibration
- Transmission Fill Calibration
- Payload System Calibrations
- Machine Cooling Fan Calibrations
- Payload Correction Factor Calibration
The following calibrations can be performed to the Chassis ECM:
- Inertial Measurement Sensor Calibrations
To access the calibration procedures for the ECM, establish the connections of the Cat ET to the machine. Navigate to the calibration screen by clicking "Service" on the tool bar and then clicking "Calibrations". Select the desired calibration procedure that is required. Click the "Start" button at the bottom of the screen.
Once the specific calibration is selected, the Cat ET will guide you through the calibration procedure.
The Cat ET will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the specific instructions on the display to complete the calibration procedure.
730C 730C2 Cat ET Calibrations
Illustration 3 | g06048309 |
Calibration screen |
Transmission/Chassis ECM Calibrations
The following calibrations can be performed to the Transmission/Chassis ECM:
- Transmission Fill Calibration
- Payload System Calibrations
- Machine Cooling Fan Calibrations
- Payload Correction Factor Calibration
To access the calibration procedures for the ECM, establish the connections of the Cat ET to the machine. Navigate to the calibration screen by clicking "Service" on the tool bar and then clicking "Calibrations". Select the desired calibration procedure that is required. Click the "Start" button at the bottom of the screen.
Once the specific calibration is selected, the Cat ET will guide you through the calibration procedure.
The Cat ET will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the specific instructions on the display to complete the calibration procedure.
The following calibration can be performed to the Chassis ECM:
- Inertial Measurement Sensor Sensor Calibration
To access the calibration procedures for the Trans/Chassis ECM, establish the connections of the Cat ET to the machine. Navigate to the calibration screen by clicking "Service" on the tool bar and then clicking "Calibrations". Select the desired calibration procedure that is required. Click the "Start" button at the bottom of the screen.
Once the specific calibration is selected, the Cat ET will guide you through the calibration procedure.
The Cat ET will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the specific instructions on the display to complete the calibration procedure.