C3.4B Industrial Engine Caterpillar


Stopping the Engine

Usage:

3.4B IOPU CJ3


NOTICE

Stopping the engine immediately after it has been working under load, can result in overheating and accelerated wear of the engine components.

Avoid accelerating the engine prior to shutting it down.

Avoiding hot engine shutdowns will maximize turbocharger shaft and bearing life.


Note: Individual applications will have different control systems. Ensure that the shutoff procedures are understood. Use the following general guidelines in order to stop the engine.

  1. Remove the load from the engine. Reduce the engine speed (rpm) to low idle. Allow the engine to idle for 5 minutes in order to cool the engine.

  2. Stop the engine after the cool down period according to the shutoff system on the engine and turn the ignition key switch to the OFF position. If necessary, refer to the instructions that are provided by the OEM.

  3. Wait 60 seconds before the battery disconnect switch is turned off. The engine ECM required power after the keyswitch is turned off.

Caterpillar Information System:

CG137-08 and CG137-12 Generator Sets Engine Oil Pump
CG137-08 and CG137-12 Generator Sets Exhaust Bypass Valve
C27 Generator Set Control Panel - Inspect/Test
TH55-E70 and TH55-E90 Petroleum Transmissions Transmission Planetary - Assemble
TH55-E70 and TH55-E90 Petroleum Transmissions Transmission Planetary - Disassemble
3500 Generator Sets Coolant Level - Check
349F and 352F Excavators Hydraulic System Automatic Travel Speed Control - Test
3500 Generator Sets Coolant (ELC) - Change
3500 Generator Sets Coolant (DEAC) - Change
3512, 3508 and 3516 Generator Sets Refill Capacities
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Generator Lead Connections
2011/09/28 New Rocker Arm Assemblies Are Available for Certain C15 Truck Engines {1102, 1123}
3500 Generator Sets Coolant Temperature Regulator - Replace
C1.5 and C2.2 Industrial Engines Monitoring System - Engine Warning Indicators
C27 Generator Set Manual Stop Procedure
3516C Generator Sets Before Starting Engine
XQ400 Power Module Maintenance Recommendations
Using the U5MK1110 Ampseal Connector Kit for Wiring Harness Repairs on Perkins Engines{0374, 0599, 0701, 0709} Using the U5MK1110 Ampseal Connector Kit for Wiring Harness Repairs on Perkins Engines{0374, 0599, 0701, 0709}
Idler/Roller Assembly Machine{0374, 0599, 0729, 4159, 4180} Idler/Roller Assembly Machine{0374, 0599, 0729, 4159, 4180}
Base-Mounted Recirculating Parts Washers{0374, 0599, 0680, 0699, 0700} Base-Mounted Recirculating Parts Washers{0374, 0599, 0680, 0699, 0700}
C3.4B Engines Inlet Air Is Restricted
2011/10/13 Service Replacement Bolts and Seal Washers Are Available for the High-Pressure Fuel Pump on C175-16 Engines {1251, 1290, 7553}
3516C Generator Set Engines Coolant Temperature Is Low
3516C Generator Set Engines Oil Pressure Is Low
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.