- Caterpillar Products: All
Introduction
European Union Compliant, CE Marked
Improper operation, lubrication, maintenance, or repair of this product can be dangerous and could result in injury or death.
Do not operate or perform any lubrication, maintenance, or repair on this product. Until you have read and understood the operation, lubrication, maintenance and repair information.
Safety precautions and warnings are provided in this manual and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons.
The hazards are identified by "Safety Alert Symbol" followed by a "Signal Word" such as "DANGER","WARNING" or "CAUTION". The Safety Alert "WARNING" label is shown below.
A non-exhaustive list of operations that can cause product damage are identified by "NOTICE" labels on the product and in this publication.
Important Safety Information
Illustration 1 | g02139237 |
Think Safety |
Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. A person must be alert to potential hazards. This person must also have the necessary training, skills, and tools to perform these functions properly.
Improper operation, lubrication, maintenance, or repair of this product can be dangerous and could result in injury or death.
Do not operate or perform any lubrication, maintenance, or repair on this product. Until you have read and understood the operation, lubrication, maintenance and repair information.
Safety precautions and warnings are provided in this manual and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons.
The hazards are identified by "Safety Alert Symbol" followed by a "Signal Word" such as "DANGER","WARNING" or "CAUTION". The Safety Alert "WARNING" label is shown below.
A non-exhaustive list of operations that can cause product damage are identified by "NOTICE" labels on the product and in this publication.
Literature Information
Store this manual with the tool group.
This manual contains safety information, operation instructions and maintenance information and to be stored with the tool group.
Some photographs or illustrations in this publication may show details that can be different from your service tool. Guards and covers might have been removed for illustrative purposes.
Continuing improvement and advancement of product design might have caused changes to your service tool, which are not included in this publication.
Whenever a question arises regarding your service tool or this publication, consult the dealer for the latest available information.
The Safety section lists basic safety precautions.
Read and understand the basic precautions listed in the Safety section before operating or performing maintenance and repair on this service tool.
General Information Section
The General Information section describes tooling functions and features. This section provides useful information on individual parts, additional tooling, and resources.
Operation Section
The Operation section is a reference for the new operator and a refresher for the experienced operator.
Photographs and illustrations guide the operator through correct procedures for using the tool group.
Operating techniques outlined in this publication are basic. Skill and techniques develop as the operator gains knowledge of the service tool and the tools capabilities.
Service Parts Section
The Service Parts section describes tooling replacement parts and part number availability.
General Information Section
Introduction
The Communications Adapter 3 Group is used with a dealer supplied laptop PC and related components. The Communications Adapter 3 Group used for transmitting data from a data link connection to the PC for data logging and analysis. The Communications Adapter 3 Group includes the communications adapter, data link cable, PC, USB cable and hard shell case with foam inserts.
Minimum PC Requirements
A dealer supplied PC (Laptop Computer)is required to download and operate the Communication Adapter 3 (CA3) software.
Minimum PC requirements are:
- IBM® PC compatible with the Pentium IV 2.4 GHz processor
- 512 MB RAM minimum
- 1 GB of available hard disk drive
- 40X speed CD-ROM drive or 8X speed DVDdrive or greater
- 14.1 In XGA screen (800x600) or greater
- Built-in pointing device or mouse
- USB 1.1 or 2.0 port
- Microsoft Internet Explorer 6.0 or greater
Specifications
Communications Adapter 3 Group - Communications Adapter 3 (CA3) Group
Communications Adapter 3 Group (CA3) Group     | |
Description     | Specification     |
Operating Voltage     | 9 to 32 VDC     |
Operating Temperature     | -18 to 65° C (0 to 149° F)     |
CA3 Dimensions     | 184 x 85 x 31 mm (7.25 x 3.35 x 1.22 inch)     |
CA3 Weight (1)     | 360 g (12.7 oz)     |
Case Dimensions     | 1470 x 378 x 114 mm (18.5 x 14.9 x 4.5 inch)     |
Group Weight     | 2.54 kg (5.59 lb)     |
Supported data links     | SAE J1939 (250K) SAE J1708 (ATA) Data Link (CDL)     |
Compliance     | RP1210A     |
( 1 ) | Includes Communications Adapter 3 Group, Cable Assembly, Cable Assembly, and Case with Foam Insert |
Nomenclature
Note: Throughout this manual the Communications Adapter 3 also be referred to as the CA3.
Communications Adapter 3 (CA3) Group     | ||
Item     | Description     | QTY     |
1     | Communications Adapter 3 (CA3)     | 1     |
2     | CA3/data link Cable Assembly     | 1     |
3     | CA3/PC Cable Assembly     | 1     |
4     | Case     | 1     |
4a     | Foam Inserts     | 1     |
-     | Media CD     | 1     |
-     | Tool Operating Manual (on CD)     | 1     |
Illustration 2 | g02341517 |
Illustration 3 | g02146554 |
Illustration 4 | g02146594 |
Illustration 5 | g02146595 |
Component Storage
Note: Communications Adapter 3 (1) and related components can be stored in the Case (4) along with cable assemblies. Foam Insert (4A) are designed to accept additional optional components.
Illustration 6 | g02341530 |
(1) Communication Adapter 3 (CA3) (2) Cable Assembly (3) Cable Assembly (4) Case (4A) Foam Insert |
Operation Section
Installation of Communications Adapter 3 (CA3) Software
- Insert Media CD in laptop PC (dealer supplied) to install software and run "Comm Adapter 3.exe".
- The following screen now displayed:
"Welcome to the Comm Adapter 3 Setup Wizard. This wizard will guide you through the installation of Comm Adapter 3. Close all other applications before starting Setup."
- Click "Next" to continue.
- The Comm Adapter 3 "Choose Install Location" window will display:
"Choose Install Location"
"Setup will install Comm Adapter 3 in the following folder. To install in a different folder, click Browse and select another folder. Click Install to start the installation."
- Select a destination folder location (default is recommended unless there is a need for a different location).
- Click "Install".
Illustration 7 | g02341532 |
- The following message can appear on the Software Installation screen:
"The software you are installing has not passed Windows Logo testing to verify its compatibility with Windows XP. (Tell me why this testing is important.)"
"Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future. Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing."
- Click "Continue Anyway".
Note: Anytime this "Software Installation" message appears during the installation process, click "Continue Anyway". This message is a default message that appears when a program has not been approved by Microsoft. However, extensive measures have been taken to ensure that this software will operate correctly on your PC.
- Click "Continue Anyway".
Illustration 8 | g02394376 |
- When the following message appears, the installation is complete:
Installation Complete
Setup was completed successfully.
- Click "Close" to proceed to the next step.
Illustration 9 | g02146714 |
Note: For Windows Vista users, Steps 6-10 in this section are not necessarily to be completed, if the hardware installs automatically.
- Use Cable Assembly (3) to connect Communications Adapter 3 (1) to PC (11) USB port.
- Connect the cable to CA3 (1)
- Connect cable (3) to USB port on PC (11) .
Show/hide tableIllustration 11 g02342536
(1) Communications Adapter 3 (CA3)
(3) Cable Assembly
Illustration 10 | g02394380 |
- "Found New Hardware Wizard" window will display, prompting the installation of new hardware for the CAT CA3 with this message:
If your hardware came with an installation CD or Floppy disk, insert the CD or Floppy disk now.
- Select "Install from a list or specific location (Advanced)".
- Click "Next."
Illustration 12 | g02342539 |
(1) Communications Adapter 3 (CA3) (3) Cable Assembly (11) PC (dealer supplied). |
- The second "Found New Hardware Wizard" window will display with this message:
"Please choose your search and installation options."
- Select "Search for the best driver in these locations".
- Select "Include this location in the search:"
- Click "Browse"and select:
"C:\Program Files\Comm Adapter 3\Driver"
- Click "Next."
Illustration 13 | g02147134 |
- The following message can appear on the "Hardware Installation" screen:
The software you are installing for this hardware:
"Comm Adapter 3"
"has not passed Windows Logo testing to verify its compatibility with Windows XP. (Tell me why this testing is important.)"
"Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future. Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing."
- Click "Continue Anyway".
Illustration 14 | g02147153 |
- When the software drivers are installed, the following message will appear:
"Completing the Found New Hardware Wizard"
The wizard has finished installing the software for:
"CA3"
- Click "Finish" to close the wizard.
Illustration 15 | g02394582 |
- To view basic information about the Communications Adapter 3, perform the following:
- Navigate through "All Programs" from the "Start Menu".
- Select "Comm Adapter 3" from the "All Programs".
- Select "Comm Adapter 3 Toolkit" from the "Comm Adapter 3", in order to open the "Communication Adapter 3 Toolkit". Refer to Illustration 17.
Illustration 16 | g02147155 |
Illustration 17 | g02394856 |
How to Use the Communications Adapter 3
Using the CA3 Toolkit
- Before using the Toolkit software to upgrade firmware, connect Communications Adapter 3 (1) to dealer supplied PC (11) using Cable Assembly (3). The Toolkit does not need to be connected to a data link connection to upgrade firmware.
Note:
- Connect cable (3) to CA3 (1) .
- Connect cable (3) to USB port on PC (11).
Show/hide tableIllustration 18 g02342547
(1) Communications Adapter 3 (CA3)
(3) Cable Assembly
- To open the Communication Adapter 3 Toolkit window. Go to "Start Menu" >> "All Programs">>"Comm Adapter 3" >> "Comm Adapter 3 Toolkit" If a CA3 is connected. The Summary screen will display a few seconds after start-up.
Illustration 19 | g02342539 |
(1) Communications Adapter 3 (CA3) (3) Cable Assembly (11) PC (dealer supplied). |
- Three icon buttons are displayed at the top of the screen. Click the Summary icon button at the far left to display the Summary screen. The other two icons shown are described in Steps 4 and 7.
Illustration 20 | g02394857 |
Note: If no CA3 is connected or not being correctly detected, a "No devices detected" message will display at the bottom left of the screen. Make sure the CA3/PC USB cable is properly connected.
Illustration 21 | g02147213 |
- To update the firmware, select the middle Application Firmware Flash icon button which displays the options for firmware upgrades.
- Select a file to flash by clicking "Select File", browse to, and select the file. Click "Open".
Show/hide tableIllustration 23 g02147316
- Click "Begin Flash" to send the file. Files of the type ".tar", for example,"R35_9-MAY-08.tar"
- Once flashing begins, the status bar indicates the progress of the file transfer from the computer to the CA3.
Show/hide tableIllustration 24 g02147328
Illustration 22 | g02147214 |
- The file transfer takes approximately 2 minutes, at which point the following dialog box with the following message will display:
"The file transfer was successful. Please wait while the CA3 is reprogrammed and then resets."
- Click "OK".
Illustration 25 | g02147330 |
- The CA3 display flashes indicator lights (1A) in sequence while the new firmware is installed. When the installation is complete, the lights stop flashing. The entire transfer and installation process that take less than 4 minutes.
Illustration 26 | g02147333 |
- Click the Exit icon button on the right to exit the Toolkit.
Illustration 27 | g02342556 |
(1A) CA3 Display Indicator Lights. |
Illustration 28 | g02147373 |
Using Electronic Technician With the CA3
To use ET. The CA3 must be connected to a PC loaded with the latest version of CA3 software and to a data link connection on the machine.
- Connect CA3 (1) to PC (11) using Cable Assembly (3) .
- Connect CA3 (1) to a data link using Cable Assembly (2) .
Illustration 29 | g02342539 |
(1) Communications Adapter 3 (CA3) (3) Cable Assembly (11) PC (dealer supplied). |
- Open ET by selecting "Start Menu" >> "All Programs">> ET >> "Electronic Technician".
Note: When opening ET with CA3 for the first time, the connection of CA3 can happen based on old settings.
If this action occurs, click "Stop Connect".
Illustration 30 | g02342656 |
(1) CA3 (2) Cable Assembly |
- Go to "Utilities" >> "Preferences", and then select the "Communications" tab.
Illustration 31 | g02147394 |
- Select the appropriate communication adapter.
- Select "Comm Adapter 3 (RP1210)" from the list of available adapters.
- Select a preference (check the box) for "Enable Dual Data Link Service".
Click "OK" to save these settings.
Illustration 32 | g02147397 |
- To connect the PC to the data link through the CA3, click the "Connect" icon button.
Illustration 33 | g02147468 |
- When the CA3 is first connected, power lamp (1B) is YELLOW. In approximately one second, the light turns RED.
Illustration 34 | g02147470 |
(1B) CA3 Power Lamp |
Illustration 35 | g02342716 |
(1B) CA3 Power Lamp |
Note: While the CA3 is connected, the light for each data link will illuminate "(J1939 - RED, CDL - YELLOW, and J1708 - GREEN)".
Service Parts Section
Communications Adapter 3 (CA3) Group
Communications Adapter 3 (CA3) Group     | ||
Item     | Description     | QTY     |
1     | Communications Adapter 3 (CA3)     | 1     |
2     | CA3/data link Cable Assembly     | 1     |
3     | CA3/PC Cable Assembly     | 1     |
4     | Case     | 1     |
4a     | Foam Inserts     | 1     |
-     | Media CD     | 1     |
-     | Tool Operating Manual     | 1     |
Illustration 36 | g02341517 |
Illustration 37 | g02146554 |
Illustration 38 | g02146594 |
Illustration 39 | g02146595 |
Note: At the end of the tools operational life, dispose of the components. Recycle electrical equipment according to all Federal, state, and local guidelines.
Notes     |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |
    |