Default Settings for Discrete Input/Output Module
Digital Input and Output (DIO) Default Settings
Show/hide table
Parameter     | XQ2000 & XQ1000     | XQ1250G     |
---|---|---|
Event Input Function #1 Active State Configuration     | Low     | Low     |
Event Input Function #1 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #1 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #1 Failure Mode Identifier     | High Shutdown     | High Shutdown     |
Event Input Function #2 Active State Configuration     | Low     | High     |
Event Input Function #2 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #2 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #2 Failure Mode Identifier     | High Shutdown     | High Shutdown     |
Event Input Function #3 Active State Configuration     | Low     | Low     |
Event Input Function #3 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #3 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #3 Failure Mode Identifier     | High Warning     | High Warning     |
Event Input Function #4 Active State Configuration     | Low     | Low     |
Event Input Function #4 Event Notification Delay Time     | 0 seconds     | 0seconds     |
Event Input Function #4 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #4 Failure Mode Identifier     | High Shutdown     | High Shutdown     |
Event Input Function #5 Active State X Configuration     | Low     | Low     |
Event Input Function #5 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #5 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #5 Failure Mode Identifier     | High Warning     | High Warning     |
Event Input Function #6 Active State Configuration     | High     | High     |
Event Input Function #6 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #6 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #6 Failure Mode Identifier     | High Shutdown     | High Shutdown     |
Event Input Function #7 Active State Configuration     | Low     | Low     |
Event Input Function #7 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #7 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #7 Failure Mode Identifier     | High Warning     | High Shutdown     |
Event Input Function #8 Active State Configuration     | Low     | Low     |
Event Input Function #8 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #8 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #8 Failure Mode Identifier     | High Shutdown     | High Warning     |
Event Input Function #9 Active State Configuration     | Low     | High     |
Event Input Function #9 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #9 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #9 Failure Mode Identifier High     | High Shutdown     | Low Shutdown     |
Event Input Function #10 Active State Configuration     | Low     | Low     |
Event Input Function #10 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #10 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #10 Failure Mode Identifier     | High Warning     | Low Warning     |
Event Input Function #11 Active State Configuration     | Low     | Low     |
Event Input Function #11 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #11 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #11 Failure Mode Identifier     | High Shutdown     | Low Shutdown     |
Event Input Function #12 Active State Configuration     | Low     | Low     |
Event Input Function #12 Event Notification Delay Time     | 0 seconds     | 0 seconds     |
Event Input Function #12 Suspect Parameter Number     | Custom Event     | Custom Event     |
Event Input Function #12 Failure Mode Identifier     | High Warning     | High Shutdown     |
Event Output Function #1 Suspect Parameter Number     | Engine Coolant Temperature     | Engine Coolant Temperature     |
Event Output Function #1 Trigger Condition     | Disabled     | Disabled     |
Event Output Function #2 Suspect Parameter Number     | Engine Oil Pressure     | Engine Oil Pressure     |
Event Output Function #2 Trigger Condition     | Disabled     | Disabled     |
Event Output Function #3 Suspect Parameter Number     | Engine Coolant Temperature     | Engine Coolant Temperature     |
Event Output Function #3 Trigger Condition     | Disabled     | Disabled     |
Event Output Function #4 Suspect Parameter Number     | Fuel Level     | Fuel Level     |
Event Output Function #4 Trigger Condition     | High Warning - Specific Event     | Disabled     |
Event Output Function #5 Suspect Parameter Number     | Fuel Level     | Fuel Level     |
Event Output Function #5 Trigger Condition     | Low Warning - Specific Event     | Disabled     |
Event Output Function #6 Suspect Parameter Number     | Engine Coolant Temperature     | Engine Coolant Temperature     |
Event Output Function #6 Trigger Condition     | Warning, Shutdown, or Diagnostic - General Event     | Warning, Shutdown, or Diagnostic - General Event     |
Event Output Function #7 Suspect Parameter Number     | Generator Control Not In Automatic     | Generator Control Not In Automatic     |
Event Output Function #7 Trigger Condition     | Condition Exists - Specific Event     | Condition Exists - Specific Event     |
Event Output Function #8 Suspect Parameter Number     | Engine Speed     | Engine Speed     |
Event Output Function #8 Trigger Condition     | Disabled     | Disabled     |
Caterpillar Information System:
XQ Auto Paralleling Storage
XQ Auto Paralleling Default Settings for Electronic Modular Control Panel
XQ Auto Paralleling Default Settings for Engine Electronic Control Module
XQ Auto Paralleling Default Settings for Generator Paralleling Control
XQ Auto Paralleling Default Settings for Mode of Operation
XQ Auto Paralleling Generator Load Connections
XQ Auto Paralleling Handling
XQ Auto Paralleling Installation
XQ Auto Paralleling Initial Startup Procedure
3516C Locomotive Engines Selective Catalytic Reduction Module - Disassemble
3512C Oil Well Service Engines Product Lifting
120 and 120 AWD Motor Grader Drawbar Ball and Socket End Play - Check/Adjust
XQ Auto Paralleling Receiving Inspection
XQ Auto Paralleling Default Settings for Cat Digital Voltage Regulator
XQ Auto Paralleling Advanced Control Jumpers
XQ Auto Paralleling Power Module Controls - Check
G3306B Gas Engines Fuel Filter
C7.1 Industrial Engine Diagnostic Flash Code Retrieval
2010/09/01 Changes to the Usage and Cleaning of the Contamination Monitor Group {0645, 0680, 1280, 1348, 3080, 429F, 5095}
3500B and 3500C Marine Propulsion Engines E048 Backup ECM Took Control
C27 and C32 Engines for Caterpillar Built Machines Exhaust Cooler (NRS) - Remove and Install
2010/08/26 Service Tips for the Hydraulic Electronic Unit Injector HEUI Pump {1714}
C15 and C18 Engines Overhaul Considerations
C9.3 Industrial Engine and CX31-P600-C9I Petroleum Power Train Package Fuel System - Prime